11.4 SAR Evaluations near the Mouth/Jaw Regions of the SAM Phantom
Antennas located near the bottom of a phone may require SAR measurements around the mouth and jaw
regions of the SAM head phantom. This typically applies to clam-shell style phones that are generally longer in
the unfolded normal use positions or to certain older style long rectangular phones.
Under these circumstances, the following procedures apply, adopted from the FCC guidance on SAR handsets
document FCC KDB Publication 648474 D04v01r03. The SAR required in these regions of SAM should be
measured using a flat phantom. The phone should be positioned with a separation distance of 4 mm between
the ear reference point (ERP) and the outer surface of the flat phantom shell. While maintaining this distance at
the ERP location, the low (bottom) edge of the phone should be lowered from the phantom to establish the
same separation distance between the peak SAR locations identified by the truncated partial SAR distribution
measured with the SAM phantom. The distance from the peak SAR location to the phone is determined by the
straight line passing perpendicularly through the phantom surface. When it is not feasible to maintain 4 mm
separation at the ERP while also establishing the required separation at the peak SAR location, the top edge of
the phone will be allowed to touch the phantom with a separation < 4 mm at the ERP. The phone should not be
tilted to the left or right while placed in this inclined position to the flat phantom.
11.5 Body Worn Accessory Configurations
To position the device parallel to the phantom surface with either keypad up or down.
To adjust the device parallel to the flat phantom.
To adjust the distance between the device surface and the flat phantom to 10 mm or holster surface and
the flat phantom to 0 mm.
Fig.11.5 Illustration for Body Worn Position