The dielectric parameters of liquids were verified prior to the SAR evaluation using a Speag Dielectric Probe Kit
and an Agilent Network Analyzer.
The following table shows the measuring results for simulating liquid.
Frequency
(MHz)
Liquid
Type
Liquid
Temp.
(℃)
Conductivity
(σ)
Permittivity
(εr)
Conductivity
Target(σ)
Permittivity
Target(εr)
Delta
(σ)%
Delta
(εr)%
Limit
(%)
Date
(mm/dd/yy)
835
Head
22.4
0.92
41.14
0.9
41.5
2.22
-0.87
±5
12.17.2019
1800
Head
22.8
1.38
40.18
1.40
40.0
-1.43
0.45
±5
12.11.2019
1900
Head
22.8
1.41
39.78
1.4
40.0
0.71
-0.55
±5
12.11.2019
2450
Head
22.7
1.82
39.48
1.8
39.2
1.11
0.71
±5
12.10.2019
2600
Head
22.7
2.01
38.53
1.96
39.0
2.55
-1.21
±5
12.10.2019
835
Body
22.3
0.99
54.68
0.97
55.2
2.06
-0.94
±5
12.13.2019
1800
Body
22.4
1.50
52.82
1.52
53.3
-1.32
-0.9
±5
12.09.2019
1900
Body
22.4
1.54
52.31
1.52
53.3
1.32
-1.86
±5
12.09.2019
2450
Body
22.8
1.95
53.29
1.95
52.7
0
1.12
±5
12.23.2019
2600
Body
22.8
2.19
52.07
2.16
52.5
1.39
-0.82
±5
12.23.2019