Product Info

Report No: CCISE191202301-V01
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1912023
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: info@ccis-cb.com Page 18 of 171
8.9 Test Equipment List
Manufacturer
Equipment Description
Model
S/N
Cal. Information
Last Cal.
Due Date
SPEAG
835MHz System Validation Kit
D835V2
4d154
06.11.2019
06.10.2022
MVG
COMOSAR 1800 MHz REFERENCE
DIPOLE
SID1800
SN 09/15 DIP
1G800-360
02.28.2018
02.27.2021
SPEAG
1900MHz System Validation Kit
D1900V2
5d175
06.11.2019
06.10.2022
SPEAG
2450MHz System Validation Kit
D2450V2
910
06.10.2019
06.09.2022
SPEAG
2600MHz System Validation Kit
D2600V2
1114
11.05.2018
11.04.2021
SPEAG
Data Acquisition Electronics
DAE4
1373
08.09.2019
08.08.2020
SPEAG
Dosimetric E-Field Probe
EX3DV4
3924
08.30.2019
08.29.2020
SPEAG
DASY 52 Measurement Software
DASY 52
Version:
52.8.8.1222
N.C.R
N.C.R
SPEAG
DASY 52 File Conversion Software
SEMCAD X
Version: 14.6.10
(7331)
N.C.R
N.C.R
SPEAG
Phantom
Twin Phantom
1765
N.C.R
N.C.R
SPEAG
Phantom
ELI V5.0
1208
N.C.R
N.C.R
SPEAG
Phone Positioner
N/A
N/A
N.C.R
N.C.R
Stäubli
Robot
TX60L
F13/5P6VB1/A/01
N.C.R
N.C.R
Anritsu
Universal Radio Communication
Analyzer
MT8820C
6201060814
03.18.2019
03.17.2020
R&S
Universal Radio Communication Tester
CMU200
113097
03.18.2019
03.17.2020
HP
Network Analyzer
8753D
3410A06291
07.22.2019
07.21.2020
Agilent
Spectrum Analyzer
ESRP7
101070
03.18.2019
03.17.2020
R&S
Spectrum Analyzer
FSP30
101454
03.18.2019
03.17.2020
R&S
Signal Generator
N5182A
MY49060014
11.10.2019
11.09.2020
Huber Suhner
RF Cable
SUCOFLEX
12341
See Note 3
Huber Suhner
RF Cable
SUCOFLEX
17268
See Note 3
Huber Suhner
RF Cable
SUCOFLEX
2080
See Note 3
Weinschel
Attenuator
23-3-34
BL5513
See Note 3
Anritsu
Directional Coupler
MP654A
100217491
See Note 3
SPEAG
Dielectric Assessment Kit
3.5 Probe
1119
See Note 4
SPEAG
DAK Measurement Software
DAK
Version: DAK 3.5
N.C.R
Mini-circuits
Low Noise Amplifier
Power
amplifier
LNA-00500200-
2515
See Note 5
Note:
1. The calibration certificate of DASY can be referred to appendix C of this report.
2. Referring to KDB 865664 D01v01r04, the dipole calibration interval can be extended to 3 years with justification. The
dipoles are also not physically damaged, or repaired during the interval.
3. The Insertion Loss calibration of Dual Directional Coupler and Attenuator were characterized via the network analyzer
and compensated during system check.
4. The dielectric probe kit was calibrated via the network analyzer, with the specified procedure (calibrated in pure water)
and calibration kit (standard) short circuit, before the dielectric measurement. The specific procedure and calibration kit
are provided by Speag.
5. In system check we need to monitor the level on the spectrum analyzer, and adjust the power amplifier level to have
precise power level to the dipole; the measured SAR will be normalized to 1 W input power according to the ratio of 1
W to the input power to the dipole. For system check, the calibration of the power amplifier is deemed not critically
required for correct measurement; the spectrum analyzer is critical and we do have calibration for it
6. Attenuator insertion loss is calibrated by the network Analyzer, which the calibration is valid, before system check.
7. N.C.R means No Calibration Requirement.