Product Info

Report No: CCISE191202301-V01
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1912023
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: info@ccis-cb.com Page 165 of 171
Dipole Impedance and Return Loss calibration Report
Object:
D2600V2 - SN: 1116
Calibration Date:
November 07, 2019
Calibration reference:
IEEE Std 1528:2013, IEC 62209-1:2016, FCC KDB 865664
D01
Calibrated By:
(Janet Wei, SAR project engineer)
Reviewed By:
(Winner Zhang, Technical manager)
Environment of Test Site
Temperature:
18 ~ 25C
Humidity:
50~60% RH
Atmospheric Pressure:
1011 mbar
Test Data
Measurement Plot for Head TSL In 2019
Measurement Plot for Body TSL In 2019
Comparison with Original report
Items
TTL
Calibrated By
CCIS In 2019
Deviation
Limit
Impendence for Head TSL
49.44Ω-5.08jΩ
49.78Ω-5.11jΩ
0.34Ω-0.03jΩ
±5Ω
Return Loss for Head TSL
-25.78dB
-25.81dB
-0.12%
±20%(No less than 20 dB)
Impendence for Body TSL
46.72Ω-5.55jΩ
45.29Ω-3.29jΩ
-1.43Ω+2.26jΩ
±5Ω
Return Loss for Body TSL
-23.54dB
-24.14dB
-2.55%
±20%(No less than 20 dB)
Result
Compliance