Installation Guide
44
45
The display console of the Logia 7-in-1 Wireless Weather Station with Wi-
®
, Everlasting Solar Cell,
and 7” Full-Color HD LCD Display can be paired with other add-on sensors like the indoor hygro-thermo
and soil moisture & temperature add-on sensors.
Visit www.logiaweatherstations.com for the most updated list of compatible Logia add-on sensors.
FACTORY RESET
• To reset the console and start again, press the RESET button once or remove the backup battery
and then unplug the adapter.
• To revert back to factory settings and remove all data, press and hold the RESET button for six
(6) seconds.
30
8.4 WIRELESS 7-IN-1 SENSOR ARRAY MAINTENANCE
REPLACE THE WIND VANE
Unscrew and remove the wind
vane for replacement
REPLACE THE WIND CUP
1.
Unscrew and remove the
top cap
2. Remove the wind cup for
replacement
CLEANING THE RAIN COLLECTOR
1. Rotate the rain collector by turning
it 30°anti-clockwise.
2. Gently remove the rain collector.
3.Clean and remove any debris or
insects.
4.Install the collector when it is clean
and fully dried.
CLEANING THE UV SENSOR AND
CALIBRATION
• For precision UV measurement,
gentle clean the UV sensor cover
• Over time, the UV sensor will
naturally degrade. The UV sensor
can be calibrated with a utility
grade UV meter, please refer to
Calibration section in previous
page for about the UV sensor
cablibration.
CLEANING HYGRO-THERMO
SENSOR
1. Remove the 2 screws at the
bottom of the radiation shield.
2. Gently pull out the shield.
3. Carefully remove any dirt or
insects on the sensor and
ventilation fan (do not let the
sensors inside get wet).
4.Clean the shield with water to
remove any dirt or insects.
5.Install all the parts back when
they are clean and fully dried.
9. TROUBLESHOOT
Problems Solution
7-in-1 wireless sensor
is intermittent or no
connection
1. Make sure the sensor is within the transmission range
2. If it still does not work, reset the sensor and resynchronize with console
Additional wireless
sensor(s) is/are
intermittent or no
connection
1. Make sure the sensor(s) is/are within the transmission range
2. Make sure the channel displayed match to the channel selection on sensor
3. If it still does not work, reset the sensor and resynchronize with console
No WI-FI connection 1. Check the WI-FI icon on the display, it should be on if connectivity is
successful
2. In the console SETUP page, make sure the WI-FI settings (router's name,
security type, password) are correct
3. Make sure you connect to 2.4G band of the WI-FI router (5G not
supported)
Data not reporting to
ProWeatherLive
1. In the console SETUP page, ensure your Station ID and Station Key are
correct
2. In the "Edit Devices" of the console on PWL, ensure the Device Mac
address is entered correctly
Multi-day forecast, cloud
cover, visibility, sunrise/
sunset, moon rise/
moon set times are not
accurate
1. Ensure your console is connected to PWL
2. Ensure latitude, longitude & time zone in "Edit Devices" of the console on
PWL are correct
3. Press the [ REFRESH ] key to update the data instantly
Sunrise/sunset, moon
rise/moon set times are
dierent to that of PWL
1. Ensure your console is connected to PWL
2. Ensure the console Time Sync is set to ON
Rainfall is not correct 1. Make sure the rain collector is clean for the tiping bucket to tip smoothly
2. Make sure the sensor has stable and level mounting to ensure correct
tipping
Replacing the Wind Cup
1. Remove the rubber cup and
unscrew the wind cups.
2. Remove the wind cups for
the new replacement.
Cleaning the UV Sensor and
Calibration
• For precision UV measurement,
gently clean the UV sensor cover
lens with damp micro-ber cloth.
• Over time, the UV sensor will
naturally degrade. The UV sensor
can be calibrated with a utility
grade UV meter.
Cleaning the Rain Funnel
1. Unscrew the rain funnel by turning
the rain funnel counterclockwise.
2. Gently remove the rain funnel.
3. Clean and remove any debris or
insects from the rain funnel.
4. Install the rain funnel when it is
clean and fully dried.
Cleaning the Hygro-thermo
Sensor
1. Remove the two (2) screws at
the bottom of the radiation shield.
2. Gently remove the shield.
3. Carefully remove any dirt or
insects on the sensor (do not let
the sensors inside get wet).
4. Clean the shield with water to
remove any dirt or insects.
5. Install all the parts back when
they are clean and fully dried.
Replacing the Wind Vane
1. Unscrew and remove the wind
vane for the new replacement.
COMPATIBLE DEVICES
TROUBLESHOOTING
7-in-1 wireless sensor is not connecting.
Additional wireless sensor(s) are
not connecting.
1. Make sure the sensor(s) is/are within the transmission range.
2. Make sure the channel displayed matches the channel selection on sensor.
3. If it still does not work, reset the sensor and resynchronize with console.
No Wi-fi connection 1. Check the WI-FI icon on the display, it should be on if connectivity is
successful.
2. In the console SETUP page, make sure the WI-FI settings (router's name,
security type and password) are correct.
3. Make sure you connect to 2.4G band of the WI-FI router (5G not supported).
Display screen is not working. 1. Check that the power adapter is plugged into the console and outlet properly.
2. Reset the console by pressing the RESET button that located on the back
of the console.
Temperature is too high in the daytime. 1. Place the sensor in open area and at least 4.9 (1.5 m) o the ground.
2. Ensure that the sensor is placed away from heat generating sources or
structures, such as buildings, pavement, walls, or air conditioning units.
Some condensation beneath the UV
sensor may occur overnight.
This will disappear when temperature rises up under the sun and will not
aect the performance of the unit.
Data isn’t transferring to
ProWeatherLive, Weather Underground,
or Weather Cloud.
1. In the console SETUP page, ensure your Station ID and Station Key are
correct.
2. Ensure the date and time is correct on the console.
3. Ensure your time zone is set properly.
Weather Underground accumulation
graph’s reset time is o by an hour.
1. Ensure your time zone on Weather Underground is set properly.
2. Ensure the time zone and DST setting on your console are correct.
Rainfall data is not correct. 1. Make sure the rain collector is clean for the tipping bucket to tip smoothly.
2. Make sure the sensor has stable and level to ensure correct tipping.
PROBLEM SOLUTION
1. Make sure the sensor is within the transmission range.
2. If it still does not work, reset the sensor, and resynchronize with console.
BATTERY REPLACEMENT
If the low battery indicator icon is displayed near the antenna icon of the sensor(s), this
indicates that the batteries in your wireless weather sensor(s) are running low and should be
replaced. Make sure to replace all batteries at the same time.
CARE AND MAINTENANCE