Installation Guide
32
33
OTHER SETTING
DATA LOG SETTING
Calibration for Channel(s) Parameter
Calibration Parameter
1. Press the right key to enter channel calibration screen.
2. Press / key to adjust the value.
3. Press the left or right key to select dierent parameter.
4. Press the up or down key to select dierent row of the parameter.
5. When nished, press the right key to go back to the calibration screen or press the HOME
button to go to the home screen.
NOTE: Press the reset value key to reset the selected calibration value to default.
Sensor Parameter
Type of
calibration
Default
value
Setting range Typical calibration source
Indoor,
Outdoor or
channel(s)
Temperature Oset
Oset
Oset
Oset
Oset
0 ±68 °F Red spirit or mercury
thermometer
Humidity 0 ±20 % Sling psychrometer
Indoor
Absolute
pressure
0 ±560hPa (±16.54inHg
or ±420mmHg)
Calibrated laboratory grade
barometer
Relative
pressure
0
±560hPa (±16.54inHg
or ±420mmHg)
Local airport
Outdoor
Wind speed Gain 1 x 0.5 ~1.5 Calibrated laboratory grade
wind meter
Wind
direction
0 ±10° GPS or Compass
Rain Gain 1 x 0.5 ~1.5 Sight glass rain gauge with
meter
UVI Gain 1 x 0.01 ~ 10.0 Calibrated laboratory grade
UV meter
Light
intensity
Gain 1 x 0.01 ~ 10.0 Calibrated laboratory grade
solar radiation sensor
31
Outdoor
Wind speed Gain 1 x 0.5 ~1.5 Calibrated laboratory grade
wind meter
Wind
direction
Oset 0 ±10° GPS or Compass
Rain Gain 1 x 0.5 ~1.5 Sight glass rain gauge with
meter
UVI Gain 1 x 0.01 ~ 10.0 Calibrated laboratory grade
UV meter
Light
intensity
Gain 1 x 0.01 ~ 10.0 Calibrated laboratory grade
solar radiation sensor
4.9.8 OTHER SETTING
a
b
c
d
e
f
g
In this section, press / key to select the sub items.
# Sub item Operation / Description
a Set your region
Press / key to select Europe, UK, US, Australia
b Enable Access Point
Press key to start AP mode for WI-FI connection setup
c WI-FI status Show the current console WI-FI connection status
d Mac address Show the console Mac address
e System rmware version Show current system rmware version of the console
f WI-FI rmware version Show current WI-FI rmware version of the console
g Erase all data
Press key to erase all the data in console
h Factory reset
Press key to reset all the setting to default and clear all the data in
console
NOTE:
- Default unit display setting for dierent regions:
Unit display Europe UK US Australia
Date format D / M D / M M / D D / M
Time format 24 Hours AM / PM AM / PM AM / PM
Time zone +2 +0 -5(EST) +10
Hemisphere NORTH NORTH NORTH SOUTH
DST Auto Auto Auto O
Temperature C C F C
Pressure hPa hPa inHg hPa
Wind speed m/s m/s mph m/s
Rain mm mm in mm
Light intensity Klux Klux Klux Klux
If you are not locate in above region, please select the most suitable Region Setting and manually adjust
your settings.
Press the up /down key to select option.
NOTE: Sensors that are connected to the console may activate incorrectly during installation.
Select the “Erase All Data” option to restart the console and clear all erroneous data.
# Sub item Operation / Description
a Set your region Press
/ key to select Europe, UK, US, Australia
b Enable Access Point Press
key to start AP mode for WI-FI connection setup
c WI-FI status Show the current console WI-FI connection status
d Mac address Show the console Mac address
e System firmware version Shows current system firmware version of the console
f Wi-fi firmware version Shows current Wi-fi firmware version of the console
g Erase all data Press
key to erase all the data in console
h Factory reset Press
key to reset all the setting to default and clear all the data in console
Unit display Europe UK US Australia
Date format D / M D / M M / D D / M
Time format 24 Hours AM / PM AM / PM AM / PM
Time zone +2 +0 -5(EST) +10
Hemisphere NORTH NORTH NORTH SOUTH
DST Auto Auto Auto O
Temperature C C F C
Pressure hPa hPa inHg hPa
Wind speed m/s m/s mph m/s
Rain mm mm in mm
Light intensity Klux Klux Klux Klux
32
- WI-FI connection setup is in SETUP WI-FI CONNECTION section.
4.9.8.1 ERASE ALL DATA
Prior to and during installation of the 7-in-1 sensor-array, the sensors were likely to be
triggered, resulting in erroneous measurements and data. User may clear out all these data
from the console when the nal installation is completed and start afresh.
4.9.9 DATA LOG SETTING
a
b
c
d
e
In this section, press / key to select the sub items.
# Sub item Operation / Description
a Data log
Press / key to enable or disable the data log function
b Record interval
Press / key to select the record interval between 5, 10 or 30 minutes
c Clear data log
Press key to enter clear data log screen
d Record start Show the record start date and time
e Data log remain Show the data log storage remain
5. DATA LOG FUNCTION
You can use the USB ash drive to record the weather data for further analysis.
5.1 TO START DATA RECORD
1. Format the USB ash drive to fat 32 with PC.
2. Plug the drive to the console USB port.
3. In "Data log" setting (section 4.9.9), select "enable" to start data record.
5.2 TO STOP DATA RECORD
1. In " Data log" setting (section 4.9.9), select "disable" to stop data record.
2. Un-plug the USB ash drive
5.3 DATA FORMAT AND OPERATION
When you view the USB ash drive, There may have several les listed which is base on .
The le name is: Data_YYYYMMDD_HHMMSS.csv
YYYYMMDD is the le creation date
HHMMSS is the le creation time
Each csv le can record 7 days data that start at Sunday 00:00, once the le complete it will generate
another csv le to record the data for next 7 days.
NOTE:
- To avoid the wrong time stamp of the data record, please set the console time and date correctly.
- The storage capacity is depend on the USB ash drive capacity