Operation Manual
Iris Rev. 08 â 2009
English
30
Alarms & Functi
U p A l a rm 3 . 0
A u to D o w n Of f
L o a d D e f a u l t N o
E x i t
Select the row âAuto Downâ and set the value at which the anchor must stop. Then press the
(ON)
and (DOWN) keys for at least three seconds. Once anchor casting has commenced, release the keys.
For safety reasons it is however possible to interrupt automatic descent by pressing any
instrument key.
Troubleshooting
FAULT CAUSE CORRECTIVE ACTION
Though UP or DOWN keys
are pressed, the instrument
doesn't receive any signal
from the magnetic sensor
for more than 5 seconds.
Check the sensor electric
connections.
Check if sensor operates
properly. If not, replace it.
Check the position of
sensor and magnet on
gipsy and their distance (3
mm).
Check the operation of
electric installation or
anchor windlass.
The instrumentâs power
supply voltage is lower than
10V.
Verify the battery charge or
operation of the electrics
system.
Warranty
We guarantee our products from manufacturing defects
for 2 years from the purchase date
(purchase ticket or any other purchase proof will be requested). Guarantee does not include
damages and breakage during the transport, damages and breakage due to faulty installation or
improper use. Warranty is no longer valid when repairs or servicing have been made by
unauthorized people or made with spare parts which are not original. Warranty does not include
the complete replacement of the goods and refers exclusively to the replace of faulty pieces and
necessary labour. It does not include transfer or transport expenses. The Customer will not ask for
expenses refund.