Once the “Sensor Detection” function has recognised a “Standard” type sensor instead of a
“Project” sensor, when the “Sensor Calibrat.” menu is entered again, the menu options will
“configure” themselves according to the sensor detected.
Standard and X.. Project series
sensor menu
(magnet and sensor placed
on barbotin)
Sensor Calibrat
Barb. Circ. 3 3 .0
E x i t
1000 – 1500 –2000 W Project series
sensor menu
(magnet and sensor placed
on motor
)
Sensor Calibrat
Red. Factor 5 7 . 0
E
x i t
Barbotin Circumference
In this row the user must enter the
circumference of the gipsy (in centimetres or
inches). Use the Table 1 provided to
calculate the circumference.
Settable values: centimetres or inches.
Default value, 33 cm.
Reduction Factor
In this row the user must enter the reduction
factor. See next Table 2 for the correct value
to be entered
Default value, 57.
Select with
Select value with
Confirm with
Exit
To return to the settings menu.
Confirm with