User guide

Connection Detail - Switch Voltage and Supply Voltage are different,
Say mains supply and switching 48 Volts AC from a transformer
*If a switch is not used, its input must still be wired, otherwise if its corresponding
Transmitter Function is operated in error the Receiver will immediately switch off.
NOTE
Operating when the switched
Voltage is at low as 48 Volts,
the LED’s will be very dim!
F1 Safety
F1 Switch
F2 Safety
F2 Switch
F3 Safety
F3 Switch
F4 Safety
F4 Switch
M Safety
M Switch
Power Supply
90 - 264 VAC
for control circuits
ST -
LK1
LK2
RS232
ANT
Radio Module
Internal Aerial
glue
Wire is not supplied with Lodar 96 and 97 Series systems, local wiring regulations apply
48 Volts AC
from
transformer
Secondary
Common Live
Output 1
Output 2
Output 3
Master Output
Primary
power
supply
Earth
Live (Hot)
Neutral
Secondary
Neutral
48 Volts AC
from
transformer
required for
safety circuit
Common Live Loop
Important
ALL inputs must
be wired
*see note below