Technical Specifications
Loctite® Power Grab® Express Molding & Paneling
Interior Construction Adhesive
Page 3 of 4
Modified Tensile Adhesion:
Ceramic Tile (Back):
Plaster:
Drywall:
Marble:
Cement Board (Durock):
Polystyrene Foamboard:
Plywood:
87.7 psi
81.3 psi
37.1 psi
238 psi
44.9 psi
48.7 psi
203 psi
ASTM C557 10.2
7 day cure time
Specifications: GreenGuard certified
Directions:
Tools Typically Required:
Utility knife, caulking gun.
Safety Precautions:
Wash hands after use.
Preparation:
The temperature of the product, the surfaces and the working area must be above 50°F (10°C). For best performance, apply
adhesive at 70°F (21°C). Ensure surfaces to be bonded are clean, dry, structurally sound and free of dust, grease, oil, and other
foreign contaminants. Sand glossy surfaces. Pre-cut and fit materials before applying adhesive. Cut tip of cartridge.
Application:
Using a caulking gun, apply adhesive around perimeter of large items approximately 2” from the edge, apply additional beads at
6” intervals. Finishing nails may be required every 16” to prevent warping. Join substrates within 15 minutes and press firmly.
Repositionable for 15 minutes. Achieves final strength in 12 hours and full cure in up to 14 days. Temperature, humidity, substrate
porosity and amount of adhesive used will affect cure times.
Clean-up:
Clean tools and uncured adhesive residue immediately with warm water and soap. Cured adhesive may be carefully cut away
with a sharp-edged tool.
Storage & Disposal:
PROTECT FROM FREEZING. Store in a cool, dry place at room temperature. For maximum shelf life store at 75°F (24°C). Take
unwanted product to an approved household hazardous waste transfer facility. Hardened material may be disposed of with trash.
Label Precautions:
CAUTION! Contains petroleum distillate and crystalline silica. May cause eye and skin irritation. Avoid eye and skin contact. Do
not take internally. FIRST AID: For eye contact flush with water for 15 minutes, call a physician. For skin contact, wash
thoroughly with soap and water If swallowed, call a physician or Poison Control Center. KEEP OUT OF REACH OF CHILDREN.
WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other
reproductive harm.
Refer to Safety Data Sheet (SDS) for further information.
Disclaimer:
The information and recommendations contained herein are based on our research and are believed to be accurate, but no
warranty, express or implied, is made or should be inferred. Purchasers should test the products to determine acceptable quality
and suitability for their own intended use. Nothing contained herein shall be construed to imply the nonexistence of any relevant
patents or to constitute a permission, inducement or recommendation to practice any invention covered by any patent, without
authority from the owner of the patent.