Datasheet

MSDS-No.: 422581
V001.5
O-Ring Kit W/Adh 20g 406 DE
Page 4 of 8
7.1. Precautions for safe handling
Ventilation (low level) is recommended when using large volumes
Use of dispensing equipment is recommended to minimise the risk of skin or eye contact
Hygiene measures:
Good industrial hygiene practices should be observed.
Do not eat, drink or smoke while working.
Wash hands before work breaks and after finishing work.
7.2. Conditions for safe storage, including any incompatibilities
For optimum shelf life store in original containers under refrigerated conditions at 2 - 8°C (35.6 - 46.4 °F)
7.3. Specific end use(s)
Adhesive
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Valid for
Great Britain
Ingredient ppm mg/m
3
Type Category Remarks
ETHYL CYANOACRYLATE
7085-85-0
0,3 1,5 Short Term Exposure
Limit (STEL):
EH40 WEL
Derived No-Effect Level (DNEL):
Name on list Application
Area
Route of
Exposure
Health Effect Exposure
Time
Value Remarks
Ethyl 2-cyanoacrylate
7085-85-0
worker inhalation Long term
exposure - local
effects
9,25 mg/m3
Ethyl 2-cyanoacrylate
7085-85-0
worker inhalation Long term
exposure -
systemic effects
9,25 mg/m3
Ethyl 2-cyanoacrylate
7085-85-0
general
population
inhalation Long term
exposure - local
effects
9,25 mg/m3
Ethyl 2-cyanoacrylate
7085-85-0
general
population
inhalation Long term
exposure -
systemic effects
9,25 mg/m3
8.2. Exposure controls:
Respiratory protection:
Ensure adequate ventilation.
An approved mask or respirator fitted with an organic vapour cartridge should be worn if the product is used in a poorly
ventilated area
Filter type: A
Hand protection:
The use of chemical resistant gloves such as Nitrile are recommended.
Polyethylene or polypropylene gloves are recommended when using large volumes.
Do not use PVC, rubber or nylon gloves.
Please note that in practice the working life of chemical resistant gloves may be considerably reduced as a result of many
influencing factors (e.g. temperature). Suitable risk assessment should be carried out by the end user. If signs of wear and
tear are noticed then the gloves should be replaced.
Eye protection:
Wear protective glasses.