Datasheet
TDS LOCTITE
®
290™, August-2007
Cure Speed vs. Activator
Where cure speed is unacceptably long, or large gaps are
present, applying activator to the surface will improve cure
speed. The graph below shows the breakaway strength
developed with time on M10 zinc dichromate steel nuts and
bolts using Activator 7471™ and 7649™ and tested according
to ISO 10964.
% of Full Strength on Steel
Cure Time
100
75
50
25
0
1min 5min10min 30min 1h 3h 6h 24h 72h
Activator 7471™
Activator 7649™
No activator
TYPICAL PROPERTIES OF CURED MATERIAL
Physical Properties:
Coefficient of Thermal Expansion,
ISO 11359-2, K
-1
80×10
-6
Coefficient of Thermal Conductivity, ISO 8302,
W/(m·K)
0.1
Specific Heat, kJ/(kg·K) 0.3
TYPICAL PERFORMANCE OF CURED MATERIAL
Adhesive Properties
After 24 hours @ 22 °C
Breakaway Torque, ISO 10964:
M10 steel nuts and bolts N·m 10
(lb.in.) (90)
Prevail Torque, ISO 10964:
M10 steel nuts and bolts N·m 29
(lb.in.) (260)
Breakloose Torque, ISO 10964, Pre-torqued to 5 N·m:
M10 steel nuts and bolts N·m 30
(lb.in.) (270)
Max. Prevail Torque, ISO 10964, Pre-torqued to 5 N·m:
M10 steel nuts and bolts N·m 40
(lb.in.) (350)
Compressive Shear Strength, ISO 10123:
Steel pins and collars N/mm² ≥5.4
LMS
(psi) (≥780)
TYPICAL ENVIRONMENTAL RESISTANCE
Cured for 1 week @ 22 °C
Breakloose Torque, ISO 10964, Pre-torqued to 5 N·m:
M10 zinc phosphate steel nuts and bolts:
Hot Strength
Tested at temperature
% Strength @ 22 °C
Temperature, °C
100
75
50
25
0
0 50 100 150
Heat Aging
Aged at temperature indicated and tested @ 22 °C
% Initial Strength @ 22 °C
Exposure Time, hours
125
100
75
50
25
0
0 1000 2000 3000 4000 5000
100 °C
120 °C
150 °C
Chemical/Solvent Resistance
Aged under conditions indicated and tested @ 22 °C.
% of initial strength
Environment °C 100 h 500 h 1000 h 5000 h
Motor oil (MIL-L-46152) 125 85 85 50 50
Leaded Petrol 22 90 90 90 90
Brake fluid 22 90 90 85 85
Water/glycol 50/50 87 90 90 90 90
Acetone 22 85 85 85 85
Ethanol 22 80 80 80 80
GENERAL INFORMATION
This product is not recommended for use in pure oxygen
and/or oxygen rich systems and should not be selected as
a sealant for chlorine or other strong oxidizing materials
For safe handling information on this product, consult the
Material Safety Data Sheet (MSDS).
Where aqueous washing systems are used to clean the
surfaces before bonding, it is important to check for
compatibility of the washing solution with the adhesive. In
some cases these aqueous washes can affect the cure and
performance of the adhesive.
Henkel Loctite Americas
+860.571.5100
Henkel Loctite Europe
+49.89.320800.1800
Henkel Loctite Asia Pacific
+86.21.2891.8863
For the most direct access to local sales and technical support visit: www.loctite.com