Datasheet

SDS No.: 316211 V010.0
Loctite 243
Page 18 of 20
Hazardous substances
CAS-No.
LogPow
Temperature
Method
Tetramethylene
dimethacrylate
2082-81-7
3,1
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC
Method)
2,4,6-Triallyloxy-s-triazine
101-37-1
2,8
20 °C
not specified
2-[[2,2-bis[[(1-
oxoallyl)oxy]methyl]butoxy]
methyl]-2-ethyl-1,3-
propanediyl diacrylate
94108-97-1
4,14
30 °C
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC
Method)
Fatty acid amide
126098-16-6
> 6,5
20 °C
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC
Method)
Cumene hydroperoxide
80-15-9
2,16
not specified
Acetic acid, 2-
phenylhydrazide
114-83-0
0,74
not specified
maleic acid
110-16-7
-1,3
20 °C
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake
Flask Method)
1,4-Naphthalenedione
130-15-4
1,71
not specified
12.5. Results of PBT and vPvB assessment
Hazardous substances
CAS-No.
PBT / vPvB
Tetramethylene dimethacrylate
2082-81-7
Not fulfilling Persistent, Bioaccumulative and Toxic (PBT), very Persistent and very
Bioaccumulative (vPvB) criteria.
2,4,6-Triallyloxy-s-triazine
101-37-1
Not fulfilling Persistent, Bioaccumulative and Toxic (PBT), very Persistent and very
Bioaccumulative (vPvB) criteria.
2-[[2,2-bis[[(1-
oxoallyl)oxy]methyl]butoxy]methyl]-2-ethyl-
1,3-propanediyl diacrylate
94108-97-1
Not fulfilling Persistent, Bioaccumulative and Toxic (PBT), very Persistent and very
Bioaccumulative (vPvB) criteria.
Fatty acid amide
126098-16-6
Not fulfilling Persistent, Bioaccumulative and Toxic (PBT), very Persistent and very
Bioaccumulative (vPvB) criteria.
Cumene hydroperoxide
80-15-9
Not fulfilling Persistent, Bioaccumulative and Toxic (PBT), very Persistent and very
Bioaccumulative (vPvB) criteria.
maleic acid
110-16-7
Not fulfilling Persistent, Bioaccumulative and Toxic (PBT), very Persistent and very
Bioaccumulative (vPvB) criteria.
1,4-Naphthalenedione
130-15-4
Not fulfilling Persistent, Bioaccumulative and Toxic (PBT), very Persistent and very
Bioaccumulative (vPvB) criteria.
12.6. Other adverse effects
SECTION 13: Disposal considerations
13.1. Waste treatment methods
Product disposal:
Do not empty into drains / surface water / ground water.
Dispose of in accordance with local and national regulations.
Disposal of uncleaned packages:
After use, tubes, cartons and bottles containing residual product should be disposed of as chemically contaminated waste in an
authorised legal land fill site or incinerated.
Disposal must be made according to official regulations.
Waste code