Safety data sheet
MSDS-No.: 283439
V003.4
LOCTITE LB 8025 known as Loctite 8025 400ml,En/De/Fr/Nl
Page 9 of 11
Pentane
109-66-0
readily biodegradable
aerobic
87 %
OECD Guideline 301 F (Ready
Biodegradability: Manometric
Respirometry Test)
Naphtha, hydrotreated light,
<0,1% benzene
64742-49-0
readily biodegradable
aerobic
89 %
OECD Guideline 301 F (Ready
Biodegradability: Manometric
Respirometry Test)
12.3. Bioaccumulative potential / 12.4. Mobility in soil
Mobility:
The product evaporates readily.
The product is insoluble and floats on water.
Bioaccumulative potential:
No data available.
Hazardous components
CAS-No.
LogKow
Bioconcentration
factor (BCF)
Exposure
time
Species
Temperature
Method
Pentane
109-66-0
3,45
25 °C
OECD Guideline 107
(Partition Coefficient (n-
octanol / water), Shake
Flask Method)
Naphtha, hydrotreated light,
<0,1% benzene
64742-49-0
4 - 5,7
OECD Guideline 107
(Partition Coefficient (n-
octanol / water), Shake
Flask Method)
12.5. Results of PBT and vPvB assessment
Hazardous components
CAS-No.
PBT/vPvB
Butane, n- (< 0.1 % butadiene)
106-97-8
Not fulfilling Persistent, Bioaccumulative and Toxic (PBT), very Persistent and very
Bioaccumulative (vPvB) criteria.
Naphtha (petroleum), hydrotreated heavy
Benzene < 0,1 %
64742-48-9
Not fulfilling Persistent, Bioaccumulative and Toxic (PBT), very Persistent and very
Bioaccumulative (vPvB) criteria.
Naphtha, hydrotreated light, <0,1% benzene
64742-49-0
Not fulfilling Persistent, Bioaccumulative and Toxic (PBT), very Persistent and very
Bioaccumulative (vPvB) criteria.
Propane
74-98-6
Not fulfilling Persistent, Bioaccumulative and Toxic (PBT), very Persistent and very
Bioaccumulative (vPvB) criteria.
12.6. Other adverse effects
No data available.
SECTION 13: Disposal considerations
13.1. Waste treatment methods
Product disposal:
Dispose of according to regulations.
Disposal of uncleaned packages:
After use, tubes, cartons and bottles containing residual product should be disposed of as chemically contaminated waste in an
authorised legal land fill site or incinerated.
Disposal must be made according to official regulations.
Waste code
14 06 03 - other solvents and solvent mixtures