Certifications 2
SDS No.: 242144 V008.1
LOCTITE LB 8008 C5-A known as 8008-C5-A 453g Brush-Top,
Page 7 of 15
Derived No-Effect Level (DNEL):
Name on list
Application
Area
Route of
Exposure
Health Effect
Exposure
Time
Value
Remarks
Calcium dihydroxide
1305-62-0
Workers
Inhalation
Acute/short term
exposure - local
effects
4 mg/m3
Calcium dihydroxide
1305-62-0
Workers
Inhalation
Long term
exposure - local
effects
1 mg/m3
Calcium dihydroxide
1305-62-0
General
population
Inhalation
Acute/short term
exposure - local
effects
4 mg/m3
Calcium dihydroxide
1305-62-0
General
population
Inhalation
Long term
exposure - local
effects
1 mg/m3
Copper
7440-50-8
Workers
dermal
Acute/short term
exposure -
systemic effects
273 mg/kg
Copper
7440-50-8
General
population
inhalation
Acute/short term
exposure - local
effects
1 mg/m3
Copper
7440-50-8
General
population
inhalation
Long term
exposure - local
effects
1 mg/m3
Copper
7440-50-8
General
population
dermal
Acute/short term
exposure -
systemic effects
273 mg/kg
Copper
7440-50-8
Workers
dermal
Long term
exposure -
systemic effects
137 mg/kg
Copper
7440-50-8
General
population
dermal
Long term
exposure -
systemic effects
137 mg/kg
Copper
7440-50-8
General
population
oral
Long term
exposure -
systemic effects
0,041 mg/kg
Biological Exposure Indices:
None
8.2. Exposure controls:
Engineering controls:
Ensure good ventilation/extraction.
Respiratory protection:
Ensure adequate ventilation.
An approved mask or respirator fitted with an organic vapour cartridge should be worn if the product is used in a poorly
ventilated area
Filter type: A (EN 14387)
Hand protection:
Chemical-resistant protective gloves (EN 374).
Suitable materials for short-term contact or splashes (recommended: at least protection index 2, corresponding to > 30 minutes
permeation time as per EN 374):
nitrile rubber (NBR; >= 0.4 mm thickness)
Suitable materials for longer, direct contact (recommended: protection index 6, corresponding to > 480 minutes permeation time
as per EN 374):
nitrile rubber (NBR; >= 0.4 mm thickness)
This information is based on literature references and on information provided by glove manufacturers, or is derived by analogy
with similar substances. Please note that in practice the working life of chemical-resistant protective gloves may be considerably
shorter than the permeation time determined in accordance with EN 374 as a result of the many influencing factors (e.g.