Certifications 2
MSDS-No.: 153766
V006.0
LOCTITE EA 3463 known as Loctite 3463
Page 6 of 12
Derived No-Effect Level (DNEL):
Name on list
Application
Area
Route of
Exposure
Health Effect
Exposure
Time
Value
Remarks
Reaction product: bisphenol-A-
(epichlorhydrin); epoxy resin (number
average molecular weight <= 700)
25068-38-6
Workers
dermal
Acute/short term
exposure -
systemic effects
8,33 mg/kg
Reaction product: bisphenol-A-
(epichlorhydrin); epoxy resin (number
average molecular weight <= 700)
25068-38-6
Workers
Inhalation
Acute/short term
exposure -
systemic effects
12,25 mg/m3
Reaction product: bisphenol-A-
(epichlorhydrin); epoxy resin (number
average molecular weight <= 700)
25068-38-6
Workers
dermal
Long term
exposure -
systemic effects
8,33 mg/kg
Reaction product: bisphenol-A-
(epichlorhydrin); epoxy resin (number
average molecular weight <= 700)
25068-38-6
Workers
Inhalation
Long term
exposure -
systemic effects
12,25 mg/m3
Reaction product: bisphenol-A-
(epichlorhydrin); epoxy resin (number
average molecular weight <= 700)
25068-38-6
General
population
dermal
Acute/short term
exposure -
systemic effects
3,571 mg/kg
Reaction product: bisphenol-A-
(epichlorhydrin); epoxy resin (number
average molecular weight <= 700)
25068-38-6
General
population
dermal
Long term
exposure -
systemic effects
3,571 mg/kg
Reaction product: bisphenol-A-
(epichlorhydrin); epoxy resin (number
average molecular weight <= 700)
25068-38-6
General
population
oral
Acute/short term
exposure -
systemic effects
0,75 mg/kg
Reaction product: bisphenol-A-
(epichlorhydrin); epoxy resin (number
average molecular weight <= 700)
25068-38-6
General
population
oral
Long term
exposure -
systemic effects
0,75 mg/kg
Reaction product: bisphenol-A-
(epichlorhydrin); epoxy resin (number
average molecular weight <= 700)
25068-38-6
General
population
inhalation
Acute/short term
exposure -
systemic effects
0,75 mg/m3
Reaction product: bisphenol-A-
(epichlorhydrin); epoxy resin (number
average molecular weight <= 700)
25068-38-6
General
population
inhalation
Long term
exposure -
systemic effects
0,75 mg/m3
Biological Exposure Indices:
None
8.2. Exposure controls:
Respiratory protection:
Ensure adequate ventilation.
An approved mask or respirator fitted with an organic vapour cartridge should be worn if the product is used in a poorly
ventilated area
Filter type: A (EN 14387)