Certifications 2

SDS No.: 313071 V005.3
LOCTITE 4860
Page 13 of 15
Hazardous substances
CAS-No.
LogPow
Temperature
Method
Ethyl 2-cyanoacrylate
7085-85-0
0,776
22 °C
EU Method A.8 (Partition Coefficient)
Triethyl O-acetylcitrate
77-89-4
1,34
not specified
Hydroquinone
123-31-9
0,59
EU Method A.8 (Partition Coefficient)
Dibenzoyl peroxide
94-36-0
3,2
22 °C
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC
Method)
12.5. Results of PBT and vPvB assessment
Hazardous substances
CAS-No.
PBT / vPvB
Ethyl 2-cyanoacrylate
7085-85-0
Not fulfilling Persistent, Bioaccumulative and Toxic (PBT), very Persistent and very
Bioaccumulative (vPvB) criteria.
Triethyl O-acetylcitrate
77-89-4
Not fulfilling Persistent, Bioaccumulative and Toxic (PBT), very Persistent and very
Bioaccumulative (vPvB) criteria.
Hydroquinone
123-31-9
Not fulfilling Persistent, Bioaccumulative and Toxic (PBT), very Persistent and very
Bioaccumulative (vPvB) criteria.
Dibenzoyl peroxide
94-36-0
Not fulfilling Persistent, Bioaccumulative and Toxic (PBT), very Persistent and very
Bioaccumulative (vPvB) criteria.
12.6. Other adverse effects
SECTION 13: Disposal considerations
13.1. Waste treatment methods
Product disposal:
Cured adhesive: Dispose of as water insoluble non-toxic solid chemical in authorised landfill or incinerate under controlled
conditions.
Dispose of in accordance with local and national regulations.
Contribution of this product to waste is very insignificant in comparison to article in which it is used
Collection and delivery to recycling enterprise or other registered elimination institution.
Disposal of uncleaned packages:
After use, tubes, cartons and bottles containing residual product should be disposed of as chemically contaminated waste in an
authorised legal land fill site or incinerated.
Disposal must be made according to official regulations.