Data Sheet
TDS LOCTITE
®
5800™, April-2012
Heat Aging
Aged at temperature indicated and tested @ 22°C
% of Full Strength on Steel
Exposure Time, hours
200
150
100
50
0
0 250 500 750 1000
180 °C
120 °C
150 °C
% of Full Strength on Alumin.
Exposure Time, hours
200
150
100
50
0
0 250 500 750 1000
180 °C
150 °C
120 °C
Cured for 1 week @ 22 °C
Shear Strength
Lap Shear Strength, ISO 4587:
Grit Blasted Mild Steel (GBMS)
Chemical/Solvent Resistance
Aged under conditions indicated and tested @ 22 °C
% of initial strength
Environment °C 100 h 500 h 1000 h
Motor oil 120 140 115 135
Motor oil 150 155 150 185
Water/glycol 50/50 87 100 95 120
Water/glycol 50/50 120 115 90 70
ATF 120 130 110 130
ATF 150 135 125 160
Unleaded gasoline 22 150 100 125
GENERAL INFORMATION
This product is not recommended for use in pure oxygen
and/or oxygen rich systems and should not be selected as
a sealant for chlorine or other strong oxidizing materials.
For safe handling information on this product, consult the
Material Safety Data Sheet (MSDS).
Where aqueous washing systems are used to clean the
surfaces before bonding, it is important to check for
compatibility of the washing solution with the adhesive. In
some cases these aqueous washes can affect the cure and
performance of the adhesive.
This product is not normally recommended for use on plastics
(particularly thermoplastic materials where stress cracking of
the plastic could result). Users are recommended to confirm
compatibility of the product with such substrates.
Directions for use:
1. For best performance bond surfaces should be clean and
free from grease.
2. The product is designed for close fitting flanged parts with
gaps up to 0.25 mm.
3. Apply manually as a continuous bead or by screen
printing to one surface of the flanges.
4. Low pressures (<0.05 MPa) may be used when testing to
confirm a complete seal immediately after assembly and
before curing.
5. Flanges should be tightened as soon as possible after
assembly to avoid shimming.
Loctite Material Specification
LMS
LMS dated August-17, 2011. Test reports for each batch are
available for the indicated properties. LMS test reports include
selected QC test parameters considered appropriate to
specifications for customer use. Additionally, comprehensive
controls are in place to assure product quality and
consistency. Special customer specification requirements may
be coordinated through Henkel Quality.
Storage
Store product in the unopened container in a dry location.
Storage information may be indicated on the product container
labeling.
Optimal Storage: 8 °C to 21 °C. Storage below 8 °C or
greater than 28 °C can adversely affect product properties.
Material removed from containers may be contaminated during
use. Do not return product to the original container. Henkel
Corporation cannot assume responsibility for product which
has been contaminated or stored under conditions other than
those previously indicated. If additional information is required,
please contact your local Technical Service Center or
Customer Service Representative.
Henkel Americas
+860.571.5100
Henkel Europe
+49.89.320800.1800
Henkel Asia Pacific
+86.21.2891.8863
For the most direct access to local sales and technical support visit: www.henkel.com/industrial