SECTION 5: Firefighting measures
5.1. Extinguishing media
Suitable extinguishing media:
Carbon dioxide, foam, powder
Extinguishing media which must not be used for safety reasons:
High pressure waterjet
5.2. Special hazards arising from the substance or mixture
In the event of a fire, carbon monoxide (CO), carbon dioxide (CO2) and nitrogen oxides (NOx) can be released.
Oxides of sulfur.
Irritating organic vapours.
5.3. Advice for firefighters
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Additional information:
Do not inhale vapors and fumes., In case of fire, keep containers cool with water spray.
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
Avoid contact with skin and eyes.
Ensure adequate ventilation.
Wear protective equipment.
6.2. Environmental precautions
Do not empty into drains / surface water / ground water.
6.3. Methods and material for containment and cleaning up
For small spills wipe up with paper towel and place in container for disposal.
For large spills absorb onto inert absorbent material and place in sealed container for disposal.
Dispose of contaminated material as waste according to Section 13.
6.4. Reference to other sections
See advice in section 8
SECTION 7: Handling and storage
7.1. Precautions for safe handling
Use only in well-ventilated areas.
Avoid skin and eye contact.
Prolonged or repeated skin contact should be avoided to minimise any risk of sensitisation.
See advice in section 8
Hygiene measures:
Wash hands before work breaks and after finishing work.
Do not eat, drink or smoke while working.
Good industrial hygiene practices should be observed.
7.2. Conditions for safe storage, including any incompatibilities
Refer to Technical Data Sheet
7.3. Specific end use(s)
Adhesive