SDS
_____________________________________________________________________________________________
WPS-AGS-002 - Lock-Ease
Revision Date 07-Sep-2018
dust synthetic
(vacated) TWA: 5 mg/m
3
respirable fraction synthetic
TWA: 15 mppcf natural
Aluminum iso-propoxide
555-31-7
TWA: 1 mg/m
3
respirable
particulate matter
- -
Stearic acid
57-11-4
TWA: 10 mg/m
3
inhalable
particulate matter
TWA: 3 mg/m
3
respirable
particulate matter
- -
Ethylbenzene
100-41-4
TWA: 20 ppm TWA: 100 ppm
TWA: 435 mg/m
3
(vacated) TWA: 100 ppm
(vacated) TWA: 435 mg/m
3
(vacated) STEL: 150 ppm
(vacated) STEL: 655 mg/m
3
IDLH: 800 ppm
TWA: 100 ppm
TWA: 435 mg/m
3
STEL: 125 ppm
STEL: 545 mg/m
3
Naphthalene
91-20-3
TWA: 10 ppm
S*
TWA: 10 ppm
TWA: 50 mg/m
3
(vacated) TWA: 10 ppm
(vacated) TWA: 50 mg/m
3
(vacated) STEL: 15 ppm
(vacated) STEL: 75 mg/m
3
IDLH: 250 ppm
TWA: 10 ppm
TWA: 50 mg/m
3
STEL: 15 ppm
STEL: 75 mg/m
3
Toluene
108-88-3
TWA: 20 ppm TWA: 200 ppm
(vacated) TWA: 100 ppm
(vacated) TWA: 375 mg/m
3
(vacated) STEL: 150 ppm
(vacated) STEL: 560 mg/m
3
Ceiling: 300 ppm
IDLH: 500 ppm
TWA: 100 ppm
TWA: 375 mg/m
3
STEL: 150 ppm
STEL: 560 mg/m
3
Benzene
71-43-2
STEL = 2.5 ppm
TWA: 0.5 ppm
S*
TWA: 1 ppm
TWA: 10 ppm
(vacated) TWA: 10 ppm
(vacated) STEL: 50 ppm
(vacated) Ceiling: 25 ppm
Ceiling: 25 ppm
STEL: 5 ppm
IDLH: 500 ppm
TWA: 0.1 ppm
STEL: 1 ppm
ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value. OSHA PEL: Occupational
Safety and Health Administration - Permissible Exposure Limits. NIOSH IDLH: Immediately Dangerous to Life or Health.
Other Exposure Guidelines
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962
(11th Cir., 1992).
Appropriate engineering controls
Engineering Measures
Showers. Eyewash stations. Explosion proof ventilation systems.
Individual protection measures, such as personal protective equipment
Eye/Face Protection
Safety glasses with side-shields.
Skin and Body Protection
Wear protective gloves/clothing.
Respiratory Protection
If exposure limits are exceeded or irritation is experienced, NIOSH/MSHA approved
respiratory protection should be worn. Positive-pressure supplied air respirators may be
required for high airborne contaminant concentrations. Respiratory protection must be
provided in accordance with current local regulations.
Hygiene Measures
Do not eat, drink or smoke when using this product. Provide regular cleaning of equipment,
work area and clothing.
9. PHYSICAL AND CHEMICAL PROPERTIES
Information on basic physical and chemical properties
Physical State
Liquid.
Appearance
Dark gray.
Odor
Solvent.
Odor Threshold
No information available.
Property
Values Remarks/ - Method
pH
No data available None known
Melting Point/Range
No data available None known
Boiling Point/Boiling Range
156-197 °C / 312-387 °F None known
_____________________________________________________________________________________________
Page 5 / 12