User manual
When the ComputaLock/Alarm is to be used in a permanent location it is advised the main unit is mounted to a
solid object, for example a wall, floor, or a post, using one of the brackets supplied.
For equipment located very close to a wall or floor, use the black wall bracket provided. For equipment standing
on tables or trolleys (away from walls), the main Lock/Alarm unit can be mounted on a table/trolley leg using the
red U bracket supplied. Alternatively, the unit can be fixed to a flat table top using the wall bracket.
COMPUTALOCK/ALARM - Instructions
Installing the Battery
(a) Lift up the red cable clamp on the Lock/Alarm unit (you may find this easier if you press the centre of
the flat surface of the clamp with your thumb whilst at the same time pulling the clamp open with
your other fingers) and unwrap the cable to reveal the front cover release tabs (see diagram below).
(b) Ensure the key is in the unlocked (vertical) position and remove the front cover of the unit by pressing
in the top or bottom release tab (you will need to use a small screwdriver to help you do this) and
pulling the cover away from the base at the same time.
(c) Remove the red battery cover and fit a high quality 9 volt ALKALINE battery (MN 1604 / PP3).
Replace the battery cover and tighten screw fully.
(d) Refit the front cover of the Lock/Alarm unit (ensure the key remains in the fully unlocked position as
you do this) ensuring that BOTH release tabs click FULLY back into place.
Fitting the Lock/Alarm unit
using the wall bracket
1. Position the flat side of the bracket
against the flat surface to which you wish
to fix the Lock/Alarm unit.
2. Use the wall bracket to mark out the
holes on the surface it is to be attached.
3. For brick and concrete use a 1/4”
(6mm) diameter drill and insert the plastic
plugs supplied. For wood use a 1/8”
(3mm) diameter drill (plugs not required).
4. Follow step (a) in the ‘Installing the battery’ section above
5. Secure the wall bracket using the smaller screws through the holes at either end of the bracket (ie. the non
bossed holes) into the holes you have drilled. Using the long screws supplied, fix the lock/alarm unit through the
wall bracket and into the holes you have drilled (See diagram). Tighten all screws used with a screwdriver, ensuring
you do not over tighten and distort the metal chassis.
6. Follow steps (b) to (d) in the ‘ Installing the battery’ section. If battery already installed then omit step (c).
ComputaLock/Alarm has been designed as a deterrent to theft. The manufacturer/supplier
cannot accept any liability for personal injury, property damage or loss.
Fitting the cable fixing plates
1. On each item of equipment you wish to protect, select a flat area on the main chassis (NOT on panels or casings
which can be easily removed) which is free from air vents and mouldings.
2. Using an abrasive pad or paper. slightly roughen the area where the cable fixing plate is to be placed. Brush off any
remaining debris. Also rub the base of the cable fixing with the abrasive pad/paper.
3. Apply an even layer of adhesive to the base of the cable fixing plate and then attach one of the rubber pads to the
base and hold for 30 seconds. Be particularly careful not to allow any adhesive to come into contact with your skin.
4. Apply an even layer of adhesive to the other side of the rubber pad and then position on the selected area of the
equipment. Apply firm pressure hold for 30 seconds. Once again be very careful not to touch any adhesive.
5. Handling strength of the bond will develop in about 2-3 minutes. Full bond strength will occur within 24 hours.