Submittal Sheet

ARMOR WALL MOUNT
CONDENSING WATER HEATER
Submial Sheet
WAN-CA
Job Name: __________________________________
Location: __________________________________
Engineer: __________________________________
Agent/Wholesaler: _____________________________
Contractor: __________________________________
NOTES:
Model No. ____________________________________
Type Gas
____________________________________
Recovery Rate in GPH
_____________ @ _______
o
F Rise
Equipment Tag(s):
_____________________________________________
ARMOR™ WALL MOUNT CONDENSING WATER HEATER
Optional Equipment
Alarm on Any Failure
Condensate Neutralization Kit
Concentric Vent Kit (3” PVC/CPVC only)
ModBus Communications
BMS Gateway to LON or BacNet
SMART SYSTEM PC Software
Standard Features
>
AHRI Certified 96% Thermal Efficiency
> Wall Mounted Models
> Modulating Burner with 5:1 Turndown
> Direct-Spark Ignition
> Low NOx Operation
> Sealed Combustion
> Low Gas Pressure Operation
> Vertical & Horizontal Direct-Vent
> PVC, CPVC, Polypropylene or SS up to 100 Feet
> PVC/CPVC Sidewall Vent Termination
> Stainless Steel Heat Exchanger
> All Welded Construction, Gasketless Design
> 160 psi Working Pressure
> Natural to L.P. Conversion Kit
> Stainless Steel Circulating Pump
> Flow Switch
> Temperature & Pressure Relief Valve
> Tank Sensor
> Adjustable High Limit w/ Manual Reset
> Automatic Reset High Limit
> Condensate Trap
> Zero Clearances to Combustible Material
> 5 Year Limited Warranty (See Warranty for
Details)
> 1 Year Parts Warranty (See Warranty for Details)
Smart SystemFeatures
> SMART SYSTEM Digital Operating Control
> Multi Color Graphic LCD Display
> Built in Cascading Sequencer for up to
8 Water Heaters
> Multiple Size Water Heater Cascade
> Lead Lag
> Efficiency Optimization
> Building Management System Integration
> Modbus Communication (Optional)
>
0-10 VDC Input to Control Modulation or Set
point
> 0-10 VDC Modulation Rate Output
> 0-10 VDC Input to Enable/Disable call for heat
> Access to BMS Settings Through Graphic LCD
Display
> Low Water Flow Safety Control & Indication
> Inlet & Outlet Temperature Sensors & Readout
> Flue Temperature Sensor
> Water Heater Pump Control
> Pump Delay with Freeze Protection
> Pump Exercise
> Night Setback
> Building Recirculation Loop Pump Control
> Time Clock
> Maintenance Reminder
>
Ability to program installer name and number into
the product as service contact
> High Voltage Terminal Strip
> 120 VAC / 60 Hertz / 1 Phase Power Supply
> Pump Control Contacts
> Water Heater Pump Control Contacts
> Building Recirculation Pump Control Contacts
> Low Voltage Terminal Strip
> 24 VAC Louver Relay
> Louver Proving Switch Contacts
> Flow Switch Contacts
> Alarm on Any Failure Contacts
> Runtime Contacts
> Tank Sensor Contacts
> Cascade Contacts
> 0-10 VDC BMS External Control Contact
> 0-10 VDC Boiler Rate Output Contacts

Summary of content (2 pages)