1 Determine water heater location
8
Figure 1-2 Alcove Installation - Minimum Required Clearances
Figure 1-1 Closet Installation - Minimum Required Clearances
IMG00548
LEFT
24" SERVICE
0" MINIMUM
RIGHT
24" SERVICE
0" MINIMUM
TOP
6" MINIMUM
RIGHT
0" MINIMUM
1" MINIMUM CLEARANCE
A
ROUND VENT PIPE
OPEN FRONT
1/4" MINIMUM CLEARANCE
AROUND HOT WATER PIPES
FRONT
24" SERVICE
6" MINIMUM
*AREA OF EACH OPENING:
1 SQ. INCH PER 1000 BTU PER HOUR INPUT
WITH A MINIMUM OF 100 SQ. INCHES.
IMG00547
LEFT
24" SERVICE
0" MINIMUM
RIGHT
24" SERVICE
0" MINIMUM
6"
6"
TOP
6" MINIMUM
RIGHT
0" MINIMUM
1" MINIMUM CLEARANCE
A
ROUND VENT PIPE
VENTILATING*
AIR OPENING
CLOSED DOOR
FRONT
24" SERVICE
6" MINIMUM
VENTILATING*
AIR OPENING
1/4" MINIMUM CLEARANCE
AROUND HOT WATER PIPES
*AREA OF EACH OPENING:
1 SQ. INCH PER 1000 BTU PER HOUR INPUT
WITH A MINIMUM OF 100 SQ. INCHES.
⚠WARNING
For closet installations, CPVC or
stainless steel vent material MUST
BE used in a closet structure due to
elevated temperatures. Failure to
follow this warning could result in
fire, personal injury, or death.
Note: Service clearances are recommendations only.
Note: Service clearances are recommendations only.
⚠WARNING
For alcove installations, CPVC or
stainless steel vent material MUST
BE used in an alcove structure due
to elevated temperatures. Failure
to follow this warning could result
in fire, personal injury, or death.