Install Instructions

92
13 Troubleshooting
FAULT CAUSE CORRECTIVE ACTION
C˘˖ˋ˒ B˘˒˕ˎ˛
˒˜ R˞˗˗˒˗ː
ˋ˞˝ D˘ˎ˜ N˘˝
S˞˙˙˕ˢ Hˎˊ˝ˎˍ
Wˊ˝ˎ˛ ˝˘
S˙ˊˌˎ H ˎˊ˝˒˗ː
Sˢ˜˝ˎ˖
(C˘˖ˋ˒ O˗˕ˢ)
A DHW demand is present.
Wait until DHW demand has ended, then combi
unit should provide heated water to the space heating
system. The Noble Fire Tube does not provide
heated water during a DHW demand.
Diverter valve is not in DHW position (heated
boiler water is being provided to the combi
plate heat exchanger rather than to the
space heating system).
Check wiring harness connections between the Low
Voltage Connection Board (CN4) and the combi
diverter valve motor.
Check that diverter valve motor is operating.
Verify that the voltage between wire CN4-1 and
ground is 24 Vac during a space heating demand.
Replace combi diverter valve motor, Low Voltage
Connection Board, or wire harness.
S˙ˊˌˎ
Hˎˊ˝˒˗ː
Sˢ˜˝ˎ˖ Hˎˊ˝
E˖˒˝˝ˎ˛˜ G ˎ˝
H˘˝ D˞˛˒˗ː
ˊ DHW
D˛ˊˠ ˊ˗ˍ
˝ˑˎ C˘˖ˋ˒
B˘˒˕ˎ˛ ˍ˘ˎ˜
˗˘˝ P˛˘˟˒ˍˎ
H˘˝ E˗˘˞ːˑ
D˘˖ˎ˜˝˒ˌ H˘˝
Wˊ˝ˎ˛
(C˘˖ˋ˒ O ˗˕ˢ)
Diverter valve not operating correctly.
Verify diverter valve motor operation. If combi diverter
valve motor is operating correctly, replace the flow
group on the combi water set.
• Verify wiring harness connections between the Low
Voltage Connection Board, and the diverter valve motor,
and between the main control board and the Low
Voltage Connection Board.
• Verify that voltage between CN4-2 and ground is 24
Vac and that voltage between CN4-1 and ground is 0
Vac. If voltages are incorrect, replace the Low Voltage
Connection Board, wire harness, or main control
board.
• If voltages are correct and diverter valve motor is not
operating correctly, replace the combi diverter valve
motor.
L˘ˌ˔˘˞˝!
Wˊ˝ˎ˛ P˛ˎ˜˜
Sˠ˒˝ˌˑ
Water pressure switch open.
• Verify water pressure at boiler.
• Verify harness connection.
• Verify voltage at pressure switch.
• Replace pressure switch.
Installation & Service Manual
Table 13-3 (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Boiler Interface
FIRE TUBE