3 MODULE FEATURES
Power input may be provided either by the provided AC adapter (90-250 VAC 50/60 Hz) or an
optional DC input pigtail (9-32 VDC).
Precise six digit display plus sign (+9.9.9.9.9.9./-9.9.9.9.9.9.) provides properly scaled output (in
selectable units and precision) for compatible Loadstar sensor inputs..
Connected sensor(s) are powered by the display module. No additional power supply is required.
Front panel “TARE” button to simultaneously zero all connected load cells.
Front panel “UNITS” button to conveniently toggle display units between LBS, KG or N.
Front panel SHIFT, ENTER, UP and DOWN buttons for access to the powerful programming
menus.
Remote input connector contacts may be used to synchronize the internal program or tare currently
connected sensors.
Dual SPST relay contacts provide NO (Normally OPEN) and NC (Normally CLOSED) contacts
under program control.
Each relay is independently programmed and activated. Output logic sequencing, load band
activation, sensor hysteresis, set-point control, and pulsed output periods are all user
programmable.
Password protected menu for program protection.
All programming parameters are automatically stored in non-volatile memory.
Optional Lithium-Ion Polymer backup battery can be used to keep DS-3000 and attached sensors
alive during power failure conditions. The internal battery is automatically recharged when
sufficient external power is available. A convenient front panel indicator, shows when the internal
battery is charging.