Owner manual
DS-3000U DS3000 User Guide
Loadstar Sensors, Inc.
Page: 45 / 48 033-01419 Rev. 4
RS1©
RS2©
RS3©
RS4©
Remove sensor 1 from displayed sum.
Remove sensor 2 from displayed sum.
Remove sensor 3 from displayed sum.
Remove sensor 4 from displayed sum.
Summary:
Determine which input sensors are summed in the current display.
11.15 MODEL©
Function: Returns model number of connected device
Keystrokes:
This command returns the current model number of the device connected to this
virtual serial interface.
MODEL©
Request the model of the currently attached device to this
virtual COM port.
Summary:
Returns DS3000<CRLF>
11.16 UNIT© (Future Command, Not yet implemented)
Function: Sets currently active display units
Keystrokes:
This command sets the currently selected weight unit.
UNIT MLB ©
UNIT N ©
UNIT KG ©
Set UNITS to Milli-pounds.
Set UNITS to Newtons
Set UNITS to Kilograms
Summary:
Remotely sets current measurement units
11.17 SETTINGS©
Function: Returns current configuration settings
Keystrokes:
This command returns the current system configuration and programming
settings.
SETTINGS©
Summary:
Returns current configuration settings:
A
settings
DS3000 Settings V3.05