2. Once the output activates, it remains activated until the weight is greater than 25 lbs.
3. After the scale weight drops to less than 1 lb, it is assumed the customer has removed the
fertilizer and container, and the DS-3000 resets for the next cycle.
4. Lets use units of Pounds, so press the up key until the pounds lamp is illuminated.
Figure 12: Schematic for Program Example 4
9.4.3 Programming the DS-3000:
1. Press and hold menu until “Enter Pass” and “000000” appear on the display
2. Press the up or down keys to select the programming mode password (default is 000001)
3. Press enter
4. You are now in programming mode at the dsplay prompt. Press mode until you reach the
relay 1 menu.
5. Press down, to the trgr 1 entry. Press enter, and a numeric entry field will appear. Enter 25
Lbs. Press menu until the digit corresponding to the 5 is highlighted, then press up and down
to set the digit to 5. Press mode again to highlight each digit in turn, then up and down to set
each one to the correct value.
6. Press enter when you are complete. Press down to get to the next programming entry.
7. Select pnt1ra for pnt1 using the enter key to select. This will activate the output when above
this threshold.
8. Press down to trgr 2, press enter and a new numeric field appears. Enter 1.0 Lbs. Press
enter when completed.
9. Select pnt2rb for pnt2 using the enter key to select. This will reset the output once it drops
below this threshold.
10. Press down to sen1 corresponding to sensor 1. Press enter until “i” is displayed. This means
that the trigger condition will only look at sensor 1
11. Finally, press down to duratn, press enter and make sure it is set to contin.