Owner manual

DS-3000U DS3000 User Guide
Loadstar Sensors, Inc.
Page: 23 / 48 033-01419 Rev. 4
continue to hold down the enter button.
4. Release enter when the decimal point is at the desired position.
The display will retain this new decimal point selection until changed
again, or reset to the factory default.
Summary:
Manually changing the display precision.
8.2 Programming Mode Commands
Program mode is when the DS-3000 characteristics, responses and outputs are being changed by the
user. While in programming mode, the DS-3000 will not display load from attached sensors, it will
display a programming menu, summarized below, awaiting user commands. Once done editing, you’ll
need to leave programming mode and go back to run mode to see the results of any programming
changes youve made. The unit will not automatically “time out” and return to run mode once youve
entered programming mode.
8.2.1 Programming Command Summary
SHIFT/MENU
Å
UP/UNITS
DOWN/FUNCTION
Æ
DspLay tare reLay1 reLay2 Power oPtIon run
dIsp1 tare 1 trgr1 trgr1 tout led
dIsp 2 tare 2 pnt1 pnt1 bat trgt
dIsp 3 tare 3 trgr2 trgr2 S1
v3 05*
dIsp 4 tare 4 pnt2 pnt2 S2 Pass
type Sen1 Sen1S1 S3 Factor
Sen2 Sen2S2 S4
Sen3 Sen3S3
sen4 sen4s4
duratn duratn
*Version: The actual version of the firmware is displayed (e.g. v3 05).
8.2.2 Display Options Menu
Function: Display Source Select
Keystrokes:
Mode Key menu till dspLay is displayed, then press up or down buttons to
select your desired display mode, then press enter to change enabled/disabled
(decimal point lights when enabled).
dIsp1 ©
dIsp2 ©
dIsp3 ©
dIsp4 ©
Display connected Sensor 1
Display connected Sensor 2
Display Connected Sensor 3
Display Connected Sensor 4
Factory default is for all 4 displays to be on