Important Note on System Operation and Start-up:
For proper operation of the LS420 display unit it must be calibrated for the configuration
of installed sensors. The display unit powers up with several green lights flashing, this
indicates that a radio communication link is being created with all load sensors, angle
sensors, wind sensors and anti-two-block switches. Once a reliable radio communication
link is established, all green lights will remain lit without flashing.
This process takes about two minutes for sensors in sleep mode. The delay is created by
the battery management function and does not affect system security. If an anti-two-
block switch detects a pending two-block event, if a load cell detects a change in load, or
if an angle sensor detects a change in angle, the appropriate radio link will be estab-
lished in less than 1/10th of a second. To immediately wake-up a load cell, lift the hook
with a load; to immediately wake up an angle sensor, change the boom angle.
In special conditions of lockout created by a missing sensor, you may bypass that sen-
sor until the next display power up by pressing bypass for 10 seconds. That sensor
green light should stop flashing and then turn off.
Contact Information:
Corporate Office: Toll Free Ph.: (888) 819-4355 Toll Free Fax: (888) 238-4099
Load Systems International Dir. Ph.: (360) 666-5028 Dir. Fax: (360) 258-4093
P.O. Box 820486 sales@loadsystems.com
Vancouver, WA 98682
For any information visit our website www.loadsystems.com
U.S. Western Regional Office: Central/Gulf Regional Office: North Central Regional Office:
Scott Colberg Randall Perrin Terry Petzold
Toll Free Ph.: (877) 287-7011 Toll Free Ph.: (877) 278-7340 Toll Free Ph.: (877) 256-1674
Dir. Ph.: (360) 575-9518 Phone (337) 893-2322 Phone (920) 894-2785
Fax: (360) 575-8532 Fax (337) 893-0026 Fax (920) 894-4934
scolberg@loadsystems.com
rperrin@loadsystems.com
tpetzold@loadsystems.com