User's Manual
14 LS420 Universal User Manual V2.91 2003-01-21.doc
2.3 Angle Sensor Installation
Warning! The angle sensor must be installed such that the antenna is not in contact with
a metal surface or object (boom, jib, wire, chain etc.). Such contact will interfere with ra-
dio communication between the angle sensor and the display unit.
Warning! When welding the metal lugs to the boom the angle sensor must be kept well
away from the weld site and any touching metal objects.
The angle sensor is pre-calibrated at the factory; for correct installation it must be positioned
carefully, then zeroed. The bracket has two boltholes, one of which is a curved slot for fine ad-
justment. See the diagrams below for correct orientation. The angle sensor should be mounted
on the left side of the boom (as viewed from the cab) with the indicator light towards the boom
tip.
Boom
centerline.
Cabin
Boom
The angle sensor is
mounted with its hori-
zontal axis parallel to
the boom centerline.
Left side
Front
Cabin
The angle sensor is mounted
with its top/bottom axis within
15 degrees of vertical.
Front
Front
Cabin
Boom
The angle sensor must
not be mounted with its
top/bottom axis m
ore than
15 degrees from vertical.
Cabin
Boom
A wedge can be used to mount the
angle sensor with its top/bottom
axis within 15 degrees of vertical.
Boom
The angle sensor is mounted with its hor
i-
zontal axis parallel to the boom centerline.
Towards
boom tip
Indicator light
Towards
boom base