User's Manual

40 LS420 Universal User Manual V2.91 2003-01-21.doc
6.5 The Display Unit Is Always In Alarm Mode, the Load warning light
is on
If "Hoist" button green light is on press the "Hoist" button until it goes off.
Press the "Parts" button to verify that the parts of lines is consistent with actual
cable configuration. Refer to the "Parts" button section in the user manual.
If the "Tare" button light is on, press the "Tare" button once to disable the tare function
Press either the "Limit +" or the "Limit -" button to see the limit programmed for the hoist.Verify that
the limit programmed is consistent with the crane capacity in its present configuration.
Remove weight
from load cell.
The display is
always in alarm
mode: the "
Load
"
warning light
is on.
If there is an auxilliary load cell press the "Hoist" button until the "Hoist" button light is on. Repeat
the previous three steps to verify the parts of lines, tare and laod limit for the auxilliary hoist.
Does the
load displayed now
correspond with the
weight on the
load cell?
No
Yes
Is the
overload alarm
still on?
Please call your
service representative
Yes
Everything seems to be
functioning normally.
No
Verify
communication
between load cell and
display unit (follow
procedure on page x)
then return here.
Verify overload
alarm function.
Does
the overload
alarm now function
properly?
Yes
No
Press "Test" to verify
loadcell batteries.
Verify battery installation. Please pay special
attention to avoid infiltration of water or dirt and to
ensure that the load cell wires are properly connected
and not severed. Change the batteries if necessary.
Verify proper load
cell function.
Does the
load displayed now
correspond with the
weight on the
load cell?
Is the
overload alarm
still on?
Please call your
service representative
Everything seems to be
functioning normally.
Please call
your service
representative
Yes
No
No
Yes