the load connected on the lockout. An internal auto-re-settable fuse limits the current to 1
Amp. If a current higher than 1.5 Amp appears on the white wire, the fuse will trigger, cutting
the current on this circuit. The fuse will permit the normal current flow to resume a few sec-
onds after short-circuit removal. Fuse model #60R075 from www.littlefuse.com.
•
Green wire: normally not used. For optional second lockout, only when ordered.
•
Orange wire: do not connect. Display units made before July 2001 (s/n lower than 22545)
were powered with the orange wire instead of the red. This was changed to conform to indus-
try standard. Now for optional cabled A2B, only when ordered.
Black wire: negative (ground)
Red wire: +12 or 24 volts (crane power supply)
White wire: standard lockout
Green wire: for optional second lockout, only when
ordered
Orange wire:
do not connect
. For o
p-
tional cabled A2B, only when ordered.