User's Manual Part 2
ISTALLATIO
ISTALLATIO
31
31
8. Note the new trim and scale values.
9. Press Enter to save and send the new
calibration to the rope payout sensor.
10.Press Exit to return to the operation display.
2.13c Rope Payout Limits
The minimum and maximum rope payout (length)
limits and the maximum rope speed limit can be
adjusted in the display in the limit menu. The
maximum rope payout limit can be programmed to
trigger lockout when exceeded, see menu 4G)
L
OCKOUT SETTINGS. The minimum rope payout limit
and the maximum rope speed limit will trigger an
alarm when exceeded. The default limit for
maximum rope payout is 300 feet; the default
minimum limit is -300 feet. The default limit for
maximum rope speed is 15.0 feet per second.
2.13d Electrical connections
Voltage: 9 to 30 Volts DC, about 0.3 Amp
Red wire: positive voltage
Blue wire: negative or ground
Two types of connections are recommended;
1) Always powered up
2) Powered-up at the same source as the
GS820 display unit
Figure: Rope payout calibration, adjust the actual rope length
Figure: Rope payout calibration, trim and scale values