User's Manual Part 2
OPERATIO
OPERATIO
41
41
Table: Information Alerts Table: Information Alerts (Continued)
* If the lockout relay is inverted this alert will occur
when voltage is detected on the wire when safe.
** If the lockout relay is inverted this alert will occur
when voltage is not detected on the wire in alarm.
Alert:
“L
OAD ID: G15000 MAXIMUM LIMIT”
Description:
The sensor indicates a value greater than the
operator adjusted limit.
• Verify operator adjusted limits in the limit menu.
WARNING!
Do not operate the crane
beyond the limits specified by the
manufacturer.
!
!
Alert:
“A
NGLE ID: G15000 MINIMUM LIMIT”
Description:
The sensor indicates a value less than the operator
adjusted limit.
• Verify operator adjusted limits in the limit menu.
WARNING!
Do not operate the crane
beyond the limits specified by the
manufacturer.
!
!
Alert:
“L
OAD ID: G15000 LOW BATTERY”
Description:
Less than 10% of battery life remains in the sensor.
• Schedule battery replacement for the next
available opportunity. Typically several weeks
of operation remain from the moment the
sensor low battery warning is first triggered.
Alert:
“L
OAD ID: G15000 NOT RECEIVED”
Description:
The display isn’t receiving communication from the sensor.
• Verify that the sensor ID number programmed
matches the ID number of the sensor installed
on the crane. Go to menu
5A1.
Alert:
“V
ERIFY WHITE WIRE (UNEXPECTED VOLTAGE)”
Description:
Voltage is detected on the lockout wire when in alarm*.
With the standard relay configuration voltage should not
be present on a lockout wire in alarm condition.
• Verify the wire connection. Refer to the Power Supply
and Lockout Connection sub section of this manual.
Alert:
“V
ERIFY WHITE WIRE (SHORTED TO GROUND)”
Description:
Voltage is not detected on the lockout wire when
safe**. With the standard relay configuration voltage
should be present on a lockout wire in safe condition.
• Verify the wire is not shorted to ground.
• Verify the wire is not connected directly to the
valve coils; a relay should be installed between
the wire and the valve coils. Refer to the Power
Supply and Lockout Connection sub section of
this manual.
Alert:
“M
AIN OUT OF CHART”
Description:
One or more primary conditions of the chart selected
for the hoist is not met (example: telescopic boom
length).
• Verify the conditions of the selected rated
capacity chart.
Alert:
“M
AIN ANGLE ABOVE CHART MAXIMUM”
Description:
The boom or jib angle is above the maximum angle
permitted by the selected chart. (For charts
determined by radius only, this message will occur
when the radius is less than the minimum radius
permitted by the chart).
• Verify the boom and jib angles permitted by the
rated capacity chart selected.
Alert:
“M
AIN ANGLE BELOW CHART MINIMUM”
Description:
The boom or jib angle is under the minimum angle
permitted by the selected chart. (For charts
determined by radius only, this message will occur
when the radius is greater than the maximum radius
permitted by the chart).
• Verify the boom and jib angles permitted by the
rated capacity chart selected.