User's Manual
CERTIFICATIO OTES
CERTIFICATIO OTES
53
53
7.1
7.1
Model Numbers
Model Numbers
CSA and ATEX
CSA Class I, Division 1 and 2 Rated Equipment:
part numbers end with “-CSA”
Example: GC012-CSA
ATEX Zone 0 & 2: the letters “ATEX” are included
in the part numbers
Example: GC012-ATEX-CE
7.2
7.2
Important Notes for
Important Notes for
Hazardous Area Certified
Hazardous Area Certified
Components
Components
7.2a Specifications
Table: Battery type
Sensors: GCxxx-ATEX-CE series sensors, GS001-
ATEX-CE, GS002-ATEX-CE, GS010-ATEX-CE,
GS011-ATEX-CE, GS020-ATEX-CE, GS005-ATEX-
CE, GS050-ATEX-CE (all intrinsically safe):
II 1 G Ex ia IIC T4
7.2b Ensuring Safe Operation in
Hazardous Areas
7.2c Product Repair And Servicing
LSI
LSI products have no replaceable or user
serviceable parts except the antenna and the
batteries. Suggested load cell maintenance
instructions are described in the Maintenance
section of this manual. For any other suspected
problems, damage or required servicing, please
contact your closest
LSI
LSI office.
7.3
7.3
Equipment Markings
Equipment Markings
ATEX Part number (end with CSA-CE)
7.
7.
CERTIFICATION NOTES
CERTIFICATION NOTES
WARNING!
• Understand manual before operation.
• Replace batteries only in a non-hazardous
area.
• Substitution of components may impair
intrinsic safety.
• Substitution of components may impair
suitability for Class I, Division 2.
• Do not remove power cable from display
when on.
!
!
Models Battery type and
specification
GC005-ATEX-CE
GC012-ATEX-CE
GC018-ATEX-CE
GC035-ATEX-CE
GC060-ATEX-CE
GC100-ATEX-CE
GC170-ATEX-CE
GS001-ATEX-CE
GS002-ATEX-CE
GS005-ATEX-CE
GS010-01-ATEX-CE
GS010-02-ATEX-CE
GS010-03-ATEX-CE
GS-011-ATEX-CE
GS020-ATEX-CE
“D” Type
3.6 V lithium batteries
Tadiran TL-5930 model
Temperature code “T4”
GS050-ATEX-CE
“C” Type, 1.5 V alkaline
Duracell PC1400 model
Temperature code T 150°C
WARNING!
• Equipment must be correctly installed
according to the instructions desbribed in
this manual and need to be installed in
locations providing adequate protection
from impact and external damage.
• Always make sure the system works
properly. Test all componenents before
using the crane. A description of display
status and warning lights is available in the
Operation section of this manual.
!
!
C
C
W
ARNING
!
Read the operator’s manual.
Test before every use.
Batteries: replace with “C” size alkaline
Duracell model #PC1400.
T
EST
: the light on the bottom must flicker red
and green when the cable is cycled in and out.
International:
+1 281 664 1330
Built in 2008
4495 Hamel Blvd,
suite 110, Québec,
QC, Canada
Serial number is on
the front
II 1 G Ex ia IIC T150
08ATEX0068 X Issuer: 0344
Exia IIC T150
WARNING – DO NOT
REPLACE BATTERY WHEN AN
EXPLOSIVE GAS
ATMOSPHERE MAY BE
PRESENT
C
C
Model №: GS050-CSA-CE
Anti-Two-Block
Switch