User's Manual

62 Revision 2 GM550 v1043 FCC-IC.doc
Transfer Firmware Files from the Palm to a GS550
Step 1. On the Palm, start the LSI Firmware software:
a. Press the house icon to go to the Home menu.
b. Select All from the drop down menu in the upper right hand corner.
c. Select LSI Firmware.
Step 2. On the GS550 display, press and hold Bypass while starting the display. The display
will enter a safer mode and allow firmware
updates.
Step 3. Align the infrared ports of the Palm and the
GS550, about 6 inches (10 centimetres) apart.
Step 4. On the Palm, send the file:
a. Select a firmware or chart file to send from the
LSI Firmware file list.
b. Press Send. The GS550 will display
Transferring”. When the transfer is
complete the Palm generates a short musical
alarm and the GS550 displays the version
identification of the newly installed GS550
firmware.
Step 5. Repeat steps two through four to transfer any
additional files.
Tip: For advanced users only. To conserve the GS550 configuration during a firmware update read
the section that follows…
Conserve GS550 Configuration When Updating Firmware
The LSI Firmware Palm Software can conserve the actual (old) system configuration, including the
sensor list and radius parameters, when updating firmware in a GS550 display. When this option is
selected the Palm retrieves the configuration from the GS550 and saves it before sending the new
firmware. If a problem occurs during the firmware update, then the saved configuration file will be
displayed in the LSI Firmware Charts/Config list on the Palm. The configuration can then be
returned to the GS550 by following the instructions “Transfer Firmware Files from the Palm to a
GS550”
Step 1. On the Palm , start the LSI Firmware software:
a. Press the house icon to go to the Home menu.
b. Select All from the drop down menu in the upper right hand corner.
c. Select LSI Firmware.
Step 2. Correctly align the infrared ports of the Palm and the GS550.
Step 3. On the Palm, press GetCfg. The GS550 will display “Transferring”. When the
transfer is complete the Palm generates a short musical alarm and a file with the name
CONFIG# is added to the Charts/Config list.
Figure: The Palm LSI firmware list