User's Manual
GM550 v1043 FCC-IC.doc Revision 2 41
Boom Length Calibration Procedure № 2: Correct with the GS550
If displayed boom length does not match actual boom length for retracted or extended boom and if
it is not possible to easily correct by following Boom Length Calibration Procedure № 1 (previous
page), then follow this procedure. This procedure is completed in the operators cab, it requires fully
retracting, and then fully extending the boom, as prompted by the on screen instructions.
1) Parts of line 2) Crane Rigging 3) Display Settings 4) Installation
4A) Sensor List
4B) Sensor Calibr
Enter
Enter User
Password: aza
Enter
4B1) Automatic
Value Calibration
Enter
4B1A)No1 Id: xxxx
Load Cell
4B1A)No5 Id: xxxx
Len
g
th senso
r
Next
…
Enter
Length Calibration
Wizard press Next
1/8) Confirm Current
Unit: Feet
2/8) Retract the
Boom and Press
3/8) Adjust Actual
Boom Len
g
th: 33.0
4/8) Extend Boom To
Max. And Press Next
5/8) Adjust Actual
Boom Len
g
th: 105
6/8) Calib results
Offset: xx.xx
7/8) Calib results
Scale: xx.xx
8/8) Press Enter To
Save Calib In Sensor
Next Next
Next
Next Next
Next
Next
Operation
Dis
p
la
y
Next
Enter
Next Next
Enter
Next… until
Next
Enter
Figure: Boom Length Calibration Procedure № 2
Press Bypass several times to
return to the o
p
eration dis
p
la
y