User's Manual
30 Revision 2 GM550 v1043 FCC-IC.doc
Angle Sensors for the Boom or Jib
WARNING! Keep the angle sensor away from the boom and any connecting metal
structures when welding the metal lugs to the boom. Proximity to welding may cause
permanent damage to the angle sensor and prevent accurate angle indication.
Mounting Procedure
The GS010 series angle sensors can be turned on by starting up the GS550 display to which they
are programmed. The angle sensor can then assist in levelling itself with the red and green LED.
Figure: A wedge used to mount the
angle sensor with its top/bottom axis
within 15° of vertical – front view
Boom
Wedge
Cabin
Angle
sensor
Figure: Do not mount the angle
sensor with its top/bottom axis more
than 15° from vertical – front view
Boom
Angle sensor
Cabin
Figure: Angle sensor
top/bottom axis within 15°
of vertical – front view
Boom
Angle sensor
Cabin
Boom centreline
Boom
Angle sensor
Cabin
Figure: Angle sensor level with
the boom
–
side vie
w