User's Manual Part 2
GS550 UNDERHOOK
22
ChApTEr 8: CErTiFiCATiON NOTES
This device complies with Industry Canada license-exempt
RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including
interference that may cause undesired operation of the
device.
This product complies with FCC/IC radiation exposure
limits set forth for an uncontrolled environment. To
comply with RF exposure requirements, the unit must
be installed and operated with 20 cm (8 in.) or more
between the product and your body. This product may not
be collocated or operated in conjunction with any other
antenna or transmitter.
This device has been designed to operate with the
antennas listed below, and having a maximum gain of
3.0 dB. Antennas not included in this list or having a gain
greater than 3.0 dB are strictly prohibited for use with this
device. The required antenna impedance is 50 ohms.
To reduce potential radio interference to other users, the
antenna type and its gain should be so chosen that the
equivalent isotropically radiated power (e.i.r.p.) is not more
than that permitted for successful communication.
RF Exposure Warning:
antenna lIst
LSI-Robway P/N: TA011
Description: 1/4 wave monopole
MFG LSI-Robway
8.2 EMI / EMC
EMI/EMC (Electro-Magnetic Immunity & Electro-Magnetic
Compatibility):
EN 301 489-3 V1.4.1 (2002-08)
Clause 8.2: Limits for radiated emissions from ancillary
equipment, measured on a standalone basis (measuring
distance of 10m): Pass
Clause 8.3: Limits for conducted emissions DC power
input/ouput ports: Pass
Test method used: CISPR 22, EN 61000-3-2: 2000 and
EN 61000-3-3:1995+ A1:2001
All tests were performed using measurement apparatus
defined in CISPR 16-1. Radiated emissions measurements
conformed to requirements of CISPR 16-1.
Clause 8: immunity tests
Enclosure-radio frequency electromagnetic field, EN
61000-4-3: Pass
Signal – RF common mode, EN 61000-4-6: Pass
DC Power input ports, RF common mode, EN 61000-4-6:
Pass
Clause 9.2, radio frequency electromagnetic field: Pass
Clause 9.5, radio frequency common mode: Pass
ESD (Electro-Static Discharges)
LSI-Robway products are tested against norm
EN 61000-4.
Other Compliances:
• SAE J159 and SAE J987
• ASME B30.5-2000
• Franklin laboratory: LSI-Robway products are safe to
use in proximity to blasting caps
• New-York City: MEA 110-05-E, in compliance with
19.1.1(a).1 requirements of Reference Standard RS
19-2 of the Building Code
• ABS (American Bureau of Shipping)
• API Spec 2C compliant
8.3 Environmental conditions
Ambient
temperature
84º C maximum for the sensors,
and 59º C maximum for the
display
Operating
temperature
-35º C to 85º C
(-31º F to 185º F)
Humidity range 0% to 100%
whEN SENSOrS ArE uSEd, ThE AmBiENT
TEmpErATurE ShOuLd NOT BE highEr
ThAN 84ºC ANd ThE diSpLAy ShOuLd
NOT BE uSEd whEN ThE AmBiENT
TEmpErATurE iS highEr ThAN 59ºC,
OThErwiSE ThErE iS A BurN pOSSiBiLiTy.
WARNING
foR the opeRatoR’s safety, take
only the ambIent tempeRatuRe
Range Into consIdeRatIon.
ThE dEviCE ShOuLd BE uSEd wiThiN ThE
rANgE SpECiFiEd ABOvE.
WARNING
FCC ID: QVBGS000 IC: 7076A-ICGS000
FCC ID: QVBGS001 IC: 7076A-ICGS001
FCC ID: QVBGS050 IC: 7076A-ICGS050
FCC ID: QVBGS075 IC: 7076A-ICGS075
FCC ID: QVBGLC000 IC: 7076A-ICGLC000