- Linux MultiMedia Studio Computer Accessories User Manual
Appendix 3: Symbolic Constants
MN1278 05.2001
69
8. Appendix 3: Symbolic Constants
The library functions can return error codes or can be passed parameters for which a number of symbolic
constants have been defined in appropriate header files. These values are shown below.
Error Codes:
Value Symbolic Constant Meaning
0
erSUCCESS
No error
1001
erINITIALISING
Loader initialising
1002
erNOT_RUNNING
Loader not runnning
1003
erBAD_COMMAND
Unrecognised command code
1004
erBAD_ADDRESS
Invalid address received
1005
erBAD_ERASE
Flash erase failed
1006
erBAD_BURN
Flash program failed
1007
erCANNOT_OPEN_FILE
File bad or does not exist
1008
erINVALID_FORMAT
File not proper COFF format
1009
erERROR_DOWNLOADING
COFF download failed
1010
erTIMEOUT
Loader did not respond in time
1011
erDPRAM_LOCATION
DPR location out of range
1012
erNOT_ENOUGH_MEM
Insufficient memory for program
1013
erBAD_BOOT_DEVICE
Bad boot source id
1014
erCARD_NOT_FOUND
Unable to locate NextMove
1015
erINVALID_VME_TYPE
Bad VME parameter.
1016
erINVALID_NEXTMOVE_TYPE
Bad NextMove parameter.
1017
erINVALID_STRING_FORMAT
Must use NULL terminated string for
string parameters.
1018
erNO_Mint_PROMPT
Command prompt was not avaiable for
up/download. Should use MintBreak
to stop a running program.
1019
erNO_WIN95_VME_SUPPORT
NextMove/VME not currently
supported under Windows 95.
1020
erCOMMAND_ABORTED
User aborted front command
1021
erFRONT_ACTIVE
Front resource already in use
1022
erCOMMAND_INTERRUPTED
Command was not passed to MG: try
again.
1023
erRETURN_INVALID
Return code invalid. Call
getSystemErr.
1024
erFRONT_DISABLED
Immediate Command Mode has been