2.8.25 AT+RCFG
This command enables or disables configuration from the remote device by executing the remote
access hand shaking protocol. Please ask for separate document for remote configuration details.
The current setting can also be retrieved by sending this command in query format.
2.8.25.1 AT+RCFGc<cr>
Where parameter c is a character used to enable/disable the remote configuration.
C Status
‘+’ Enable
‘-‘ Disable
2.8.25.1.1 Response
<command_response>
2.8.25.2 AT+RCFG?<cr>
2.8.25.2.1 Response
<cr,lf>RCFGc<command_response> if the command is successful. Here, c- current
setting. E.g on default setup, the response will be
<cr,lf>RCFG+<command_response>
2.8.26 AT+SLEEP
This command is used to enable/disable auto-power saving feature of RS232 driver as well as low
power modes of Bluetooth device. The current setting can also be retrieved by sending this
command in query format.
2.8.26.1 AT+SLEEPc<cr>
Where parameter c is a character used to enable/disable the auto power saving feature.
c Status
‘+’ Enable
‘-‘ Disable
2.8.26.1.1 Response
<command_response>
2.8.26.2 AT+SLEEP?<cr>
2.8.26.2.1 Response
<cr,lf>SLEEPc<command_response> if the command is successful. Here, c- current
setting. E.g on default setup, the response will be <cr,lf>SLEEP-
<command_response>