User's Guide

© Copyright LM Technologies Ltd Page 64 of 70
www.lm-technologies.com
LM074 SPP with GAP Central Application v1.1
6.2.5 LM074 has settings DPIN=on, MITM=off, IO-type=no-
Input-no-output
i. Pairing with the remote device might be successful if the remote
device also has DPIN=on, MITM=off and IO-type as no one.
ii. If the remote device has MITM=on or IO type other than no input
no output, the LM074 cannot pair with that device.
7. LED Indication
7.1 Power on LED sequence
1. All LEDs blink fast during power on for 3 seconds. User can notice all
LEDs blinking approximately 6 to 7 times.
2. The module shows power on LED sequence after AT*Reset=1 and
AT*Reset=2 commands.
7.2 LED0
1. LED0 (RED LED on LM068) is constantly ON to indicate that the
module/adapter is powered and active for AT commands, Bluetooth
discovery, audio functionality.
2. If LED0 is not ON, module/adapter may not be powered correctly or
not initialised.
3. The state of LED0 is irrespective of Bluetooth connection or pairing
state.
7.3 LED1
1. LED1 (Yellow LED on adapter) indicates the data transfer in the SPP
connected state.
2. When the module/adapter is not connected to the remote SPP device,
LED1 should be OFF.
3. When the module/adapter connects to a remote SPP device, LED1 is
ON for the duration of the module/adapter receiving data or sending
data to the remote device.
4. LED1 should be off when there is no active data transfer on the
Bluetooth connection.