iv. connection termination command: e.g.
“AT*DROP=00126f357215”\r\n
v. “OK” response will be provided if the string entered has valid BT
address and module is connected to the device with entered BT
address and module is in online-command mode.
vi. “Err” response will be provided if invalid BT address, invalid length
of address is provided, module is not connected to any device.
vii. AT*drop command causes the indication message to indicate the
devices are successfully disconnected.
viii. “IND*:DISCONNECTED=00126f357215” indication message is
shown to indicate the module is disconnected from the device with
BT address 0012-6f-357215.
4.6 Firmware Upgrade commands:
4.6.1 “AT*UPGRADE”\r\n
i. Execution only command.
ii. Supported in all SPP roles (dual, master-only or slave-only).
iii. The module should not be connected to BLE or any Bluetooth
device before starting the procedure.
iv. User issues this command in SPP-connected-online-command
mode to perform the OTA-firmware-upgrade.
v. User shall enter this command with password provided for
firmware upgrade. If the password is correct, then module issues
OK response and is ready for performing firmware upgrade.