User's Guide
© Copyright LM Technologies Ltd Page 36 of 70
www.lm-technologies.com
LM074 SPP with GAP Central Application v1.1
REP*:RESP=ON
at*name=?at*name=?
OK
REP*:NAME=068LM_SPP_0104
x. Below is the sequence of messages when ECHO is OFF and RESP
is ON.
at*echo=offat*echo=off
OK
at*echo=?OK
REP*:ECHO=OFF
at*resp=?OK
REP*:RESP=ON
at*name=?OK
REP*:NAME=068LM_SPP_0104
xi. Below is the sequence of messages when ECHO and RESP are
both off. The module will show only reports for the query
commands. The module will not show any indication messages for
connect or disconnect. This is to ensure backwards compatibility
with LM048/LM058/LM072 module firmware.
at*resp=?REP*:RESP=OFF
at*echo=?REP*:ECHO=OFF
at*name=?REP*:NAME=068LM_SPP_0104
4.2.5 “AT*DCOV”\r\n
i. Query and set command
ii. Discoverable query: “AT*DCOV=?”\r\n
iii. Discoverable query report: “REP*:DCOV=ON” (Module
discoverable for classic role) or “REP*:DCOV=OFF” (Module non
discoverable for classic role)
iv. Module make discoverable command: “AT*DCOV=ON”
v. Module make non-discoverable command: “AT*DCOV=OFF”
vi. Default discoverability : “ON”
vii. Enabling discoverability may generate further events of incoming
pairing/connection requests.
4.2.6 “AT*PAIR”\r\n
i. Query and set command
ii. Pairable query: “AT*PAIR=?”\r\n
iii. Pairable query report: “REP*:PAIR=ON” (Module is in pairable
state and will give indications to host of any incoming pairing
requests)
iv. Pairable query report: “REP*:PAIR=OFF” (Module is in non-
pairable state will reject pairing request internally)
v. Module make pairable command: “AT*PAIR=ON”
vi. Module make non-pairable command: “AT*PAIR=OFF”
vii. Default Pairable: ON