Manual
Automatgevär m/42 B Manual
2000 Anders & Petter.
10
Installation of blank firing device;
Remove the muzzle plug, but not the sight carrier. Screw on the device. To avoid damage to the threads
make sure it is turned all the way in. Push the locking tab down over the sight until it snaps into place.
Remove in the reverse order.
8. Shooting gallery practice & semi-live ammunition
Gallery (kammarammunition) and semi-live (practice) ammunition is used during certain training. This
ammunition does not produce enough pressure to reliably cycle the action. Reloading should instead be
performed manually as follows;
Hold the rifle (in “fire” mode) at the ready.
Push the receiver cover forward to locking position.
Cycle the action.
9. Loading
From standing, hold the rifle in the left hand with the muzzle facing slightly upwards and the stock
supported against the waist or belt. With the right hand;
Turn the safety on.
Push the receiver cover forward until it locks to the bolt carrier.
Pull the cover back (action opens).
Insert a clip into its cut-out.
With the thumb as close to the clip as possible, push the rounds down into the magazine.
Remove the clip and insert another one.
Repeat.
Turn the safety off.
Pull the cover back.