Figure 21. Listen Mode Sequence (wanted signal is received)
4.3.4. Stopping Listen Mode
To abort Listen mode operation, the following procedure must be respected:
Program RegOpMode with ListenOn=0, ListenAbort=1, and the desired setting for the Mode bits (Sleep, Stdby, FS, Rx
or Tx mode) in a single SPI access
Program RegOpMode with ListenOn=0, ListenAbort=0, and the desired setting for the Mode bits (Sleep, Stdby, FS, Rx
or Tx mode) in a second SPI access
4.3.5. RC Timer Accuracy
All timings of the Listen Mode rely on the accuracy of the internal low-power RC oscillator. This oscillator is automatically
calibrated at the device power-up, and it is a user-transparent process.
For applications enduring large temperature variations, and for which the power supply is never removed, RC calibration can be
performed upon user request. RcCalStart in RegOsc1 can be used to trigger this calibration, and the flag RcCalDone will be set
automatically when the calibration is over.
4.4. AutoModes
Automatic modes of packet handler can be enabled by configuring the related parameters in RegAutoModes. The intermediate
mode of the Moduleis called IntermediateMode and the enter and exit conditions to/from this
intermediate mode can be configured through the parameters EnterCondition & ExitCondition.
The enter and exit conditions cannot be used independently of each other i.e. both should be enabled at the same time. The
initial and the final state is the one configured in Mode in RegOpMode. The initial & final states can be different by
configuring the modes register while the Moduleis in intermediate mode. The pictorial description of the auto modes is
shown below.
Figure 22. Auto Modes of Packet Handler
Sub GHz FSK/OOK Transceiver Module DATASHEET