Operating Instructions
WHERE TO MOUNT
The anchor/gateway can be mounted both on
walls and ce
ilings. This document only refers
to wall mounting.
When mounted
on the ceiling,
ensure that the
antenna on the
device is pulled
down for proper
covarage.
All anchors/gateways must be mounte
d
consistently at the same height from the floor.
1
2
CEILING
FLOOR
CEILING
FLOOR
h ideal = 4 m (13 ft)
h min = 2.5 m (8 ft)
WALL
Anchor/Gateway
3
If you need to mount the anchor/gateway
close to a corner, make sure to stay away at
least 50 cm (1.5 feet).
Corner
> 50 cm
(1.5 ft
)
WALL
4
The anchor/gateway is a very sensitive locating
device. F
or its optimal performance it needs to be
mounted on the exact location that is instructed by
Litum application engineering team. When you find
the correct location of the anchor/gateway, please
you choose a fixed reference point (such as a corner,
window, etc.) and take another measurement from
there to double check its location. Please make sure
that you are using a correctly scaled floor plan.
In cases that two anchors/gateways need to be
mounted closely, make sure that they are at least 2
m (6 ft) away from each other.
5
6
Devices that transmit electromagnetic signals,
such as WiFi access points, may have a negative
impact on anchor/gateway performance. If you see
such a device close to where the anchor/gateway is
instructed to be mounted, please consult with Litum
application engineering team before you proceed.
Anchor/Gateway
2
If i
t is required to install the anchor/gateway
higher than 4m (13 ft), please consult Litum.