Brochure
6
MD Series Pumps
Applications Applications
FeaturesFeatures
Series Specifications
Model Characteristics Model Characteristics
Series Specifications
Performance Curves 2-MD 230V, 50/60Hz
230 volt, 50Hz 230 volt, 60Hz
Total Head in Meters
Capacity - Liters per Minute
Capacity - Gallons per Minute
Total Head in Feet
0
1
2
3
4
5
0 5 10 15 20 25 30 35
0
4
8
12
16
0 3 6 9
2-MD SERIES
1/30 HP
Non-Submersible, In-line Use
RPM: 2700/3000
Capacity: 28 LPM
Shut Off: 3.2 m
Liquid Temperature: 66°C
Discharge: 1/2" MNPT (12.7 mm)
Intake: 1/2" FNPT (12.7 mm)
Impeller: Glass- lled polypropylene
& Ceramagnet “A” (Barium
Ferrite)
Electrical: 230V, 50/60Hz
• Impeller magnet is uncoated,
permanent high quality ceramic/
barium ferrite
• Most models have a titanium
shaft and thrust washer for
excellent wear and corrosion
resistance
• 1/30 HP open FC motor
• Glass- lled polypropylene
magnet housing and volute
• 1.1 speci c gravity
• Nitrile O-ring
• Titanium thrust washers
and shaft
• Circulation of mildly corrosive acids, alkalis, solvents, brine, plating
solutions, sterile solutions, and other mildly corrosive chemicals and
solutions that are compatible with the pump's material of construction
Item # Model Volts Hertz Amps Watts Cord List/Cert.
580012 2-MD 230 50/60 0.65 105
1.8 m
(witho
plug)
C-cCSAus
580038 2-MD 230 50/60 0.65 105 – CE
Performance Curves TE-3-MD 230V, 50/60Hz
TE-3-MD SERIES
1/20 HP
Non-Submersible, In-line Use
RPM: 2750/3200
Capacity: 31 LPM
Shut Off: 3.5 m
Liquid Temperature: 66°C
Discharge: 1/2" MNPT (12.7 mm)
Intake: 1/2" FNPT (12.7 mm)
Impeller: Glass- lled polypropylene
& Ceramagnet “A” (Barium
Ferrite)
Electrical: 230V, 50/60Hz
• Impeller magnet is uncoated,
permanent high quality ceramic/
barium ferrite
• Most models have a titanium
shaft and thrust washer for
excellent wear and corrosion
resistance
• 1/20 HP TEFC motor
• Glass- lled polypropylene
magnet housing and volute
• 1.1 speci c gravity
• Nitrile O-ring
• Titanium thrust washers
and shaft
• Circulation of mildly corrosive acids, alkalis, solvents, brine, plating
solutions, sterile solutions, and other mildly corrosive chemicals and
solutions that are compatible with the pump's material of construction
230 volt, 50Hz 230 volt, 60Hz
Total Head in Meters
Capacity - Liters per Minute
Capacity - Gallons per Minute
Total Head in Feet
0
1
2
3
4
5
6
0 5 10 15 20 25 30 35 40
0
3
6
9
12
15
18
0 2 4 6 8 10
Item # Model Volts Hertz Amps Watts Cord List/Cert.
581012 TE-3-MD 230 50/60 1.10 135
1.8 m
(witho
plug)
C-cCSAus