Control Panel Specification Sheet

Form 994601 01/2007www.LittleGiantPump.com
General Installation Instructions
WARNING: Turn off power source before installing or adjusting
this device. Failure to turn off power could result in serious or
fatal electrical shock.
1. Determine the mounting location for control panel.
Liquid tight connectors should be used on all cables
entering panel. Conduit connectors, if used, must be
sealed.
2. Check local codes and the schematic for power circuit
requirements. On the control panel, determine the
“power in” location (from the building power supply).
CAUTION: BE SURE THE POWER SUPPLY
VOLTAGE AND PHASE ARE THE SAME AS THE
PUMP MOTORS BEING INSTALLED.
3. Determine the location on the control panel for the
pump power cables and float switch cables. Drill holes
to fit the type of cable fittings to be used.
4. Attach floats as shown in Typical Installation drawing.
5. Following step-by-step instructions and wiring diagram
included with panel, complete connections of all cables.
6. Verify correct operation of control panel after installa-
tion is complete. Follow troubleshooting procedures if
necessary.
Duplex Alarm System & Pump Control
NOTE: Little Giant Pump Company cannot be responsible
for damages caused by faulty or negligent installation of this
control. We recommend that you engage the services of a
competent plumber, electrician, or qualified service person
to install this product in accordance with national and local
electrical codes.
ACCESSORIES: Some installations may require a moisture-
free junction box to house electrical connections. Model JB70
Junction Boxes are recommended. These are available with
liquid-tight connectors. The liquid-tight connectors are also
available separately.
Recommend for use on pumps up to 1 HP (120V or 230V) and/or 2 HP
(208V or 230V) provided pump amp draw does not exceed 20 running
amps or 120 starting amps.
Item Catalog
Floats
(included)
Pump Section
Alarm Section
120/208/240 VAC,
60 Hz, Single Phase
Maximum
Start Amps
Maximum
Run
Amps
120 VAC, 60 Hz
Single Phase
2 amps
40 Watts maximum
(alarm condition)
513258 1221W120H6A17A Yes, 3 120 20
14940605 1221W120X6A No 120 20
14940787 1221W120H6A17A19F Yes,4 120 20