Control Panel Detail Sheet

9500066B © SJE-Rhombus 12/16
1A Red beacon only / no audio
(must select "0" for alarm package)
1C Horn only / no visual
(must select "0" for alarm package)
HH 3A Alarm asher
H3B Manual alarm reset
H4A Redundant off
(select Option 4D if oats included)
4B Red redundant off indicator & alarm
(must select Option 4A also)
4D Redundant off oat
(must select 4A option) (select 17 option)
H5A Thermal cutout/heat sensor auto reset
(for pumps w/thermal switch leads)
H5E Seal failure circuit & red indicator (2 wire)
6A Auxiliary alarm contact, form C
(included as standard)
H 8A Elapsed time meter
H
8C
Event (cycle) counter
H 9_A Pump overload
specify amperage after number 9 followed by letter "A". ..
Example: 912A = 12 amp pump.
H 0-25 FLA
H 25-30 FLA
10E Lockable latch - NEMA 4X
10E Lockable latch - NEMA 1
H 10F Lightning arrestor
(select pump circuit breaker)
HH10K Anti-condensation heater
11C NEMA 1 alarm panel
11D NEMA 4X alarm panel
H 14B
Main disconnect (rotary style, mounted through door, non-fused,
padlockable in the OFF-position, door interlock in the ON-position)
(must select circuit breaker)
H 0-20 FLA (total of both pumps)
H 20-60 FLA (total of both pumps)
16A 10' cord in lieu of 20' (per oat)
16B 15' cord in lieu of 20' (per oat)
16C 30' cord in lieu of 20' (per oat)
16D 40' cord in lieu of 20' (per oat)
17A SJE SignalMaster
®
/ pipe clamp l (per oat)
17B SJE SignalMaster
®
/ externally weighted l (per oat)
17C Sensor Float
®
/ internally weighted s (per oat)
17D Sensor Float
®
/ externally weighted s (per oat)
17E Sensor Float
®
Mini / pipe clamp s (per oat)
17F Sensor Float
®
Mini / externally weighted s (per oat)
17J Sensor Float
®
/ pipe clamp s (per oat)
19B Lead lag selector switch
19F Fourth oat to separate alarm function from lag
19T TOA (Test/Off/Automatic) switches and pump run lights
through door mounted
19U HOA (Hand/Off/Automatic) switches and pump run lights
through door mounted
19X Door mounted pump run indicator
l Mechanically-activated s Mercury-activated
122 1 W 9 0 4 H 6A 8AC 17A
CODE DESCRIPTION
CODE DESCRIPTION
SAMPLE
122
ENCLOSURE UPSIZE
If you selected one or more of the H options, or two HH options
H
B.42
6A
MODEL
Alarm Package
Enclosure Rating
Starting Device
Pump Full Load Amps
Pump Disconnect
Float Switch Application
Options: Auxiliary alarm contact, form C,
Elapsed time meter, event (cycle) counter,
SJE SignalMaster
®
/ pipe clamp
MODEL 122
ALARM PACKAGE
0 = select options or no alarm package
1 = alarm package (includes test/normal/silence switch, fuse, red light, & horn)
ENCLOSURE RATING
I = Indoor, NEMA 1 (metal)
W = Weatherproof, NEMA 4X (engineered thermoplastic)
STARTING DEVICE
1 = magnetic motor contactor 120/208/240V
9 = magnetic motor contactor 120V only
PUMP FULL LOAD AMPS
0 = 0-7 FLA
1 = 7-15 FLA
2 = 15-20 FLA
3 = 20-30 FLA
PUMP DISCONNECTS
0 = no pump disconnect
4 = circuit breaker 120V (select STARTING DEVICE option 9 above)
120/208/240V (select STARTING DEVICE option 1 above)
FLOAT SWITCH APPLICATION
H or L = pump down or pump up (select 17 option)
X = no oats
OPTIONS Listed below
If additional features are required, call the factory for a quote on an Engineered Custom control panel.